BOP 1 KILOWATT FUNCTION GENERATOR CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
LIST Command
Characteristics for
'String' Type Waveforms
(Remote Only)
|
Maximum number of points:
- For single (global) dwell time:
5900 (high resolution)
- For <122 different dwell times:
3933
- For >126 different dwell times:
2950
Dwell time range:
93usec to 34msec
Dwell time Resolution (increment:
0.751 usec
Skip feature (a number of
steps can be skipped from the
LIST at the first run using
L1ST:COUN:SKIP)
Able to synchronize a LIST
command with multiple
BOP'S or other devices
using Trigger Port.
Able to sample output
voltage or current during
LIST command execution.
|
NOTE:
Dwell time list must match (balance)
the amplitude list
|
Waveform Graphics
Displayed on LCD (1)
for Both Local and
Remote Operation
|
Local (1): The LCD (1) represents the programming waveform graph of the
main channel, voltage for voltage mode or current for current mode.
There is no difference between programmhg and real output waveform,
as long as programmed Limits are not exceeded and the load is resistive.
The programming waveform representation does not take into account
the interaction between settings and load.
The graph timing is automatically selected for the
best waveform representation.
Remote: When using LIST commands for waveform creation/execution,
the LCD displays the actual or real waveform graphs of the main
and limit channel, voltage and current protection limit for voltage mode
and current and voltage protection limit for current mode.
Main and Limit graphs are not phase correlated.
In order to get a meaningful representation, the graph timing
must be chosen properly. It is recommended that the first value
higher than total waveform time be chosen from the 12 time selections,
spread from 0.04 second to 75 seconds.
|
(1) Local operation and LCD applies to -MG and -ME models only.
|