   BOP 1 KILOWATT FUNCTION GENERATOR CHARACTERISTICS
Specification Rating/Description Condition
Count
(Number of
Repetitions)
Range: 1 to 255
For Count = 0 the waveform is executed indefinitely until stop command is sent.
Local (1): When the count is complete or if execution is stopped using F5, the output of the unit is set to OFF (standby indicator lit). Output must be enabled (press STANDBY) to execute the waveform again

Remote: When the count is complete or the waveform is stopped using the VOLT:MODE FIX command, the output remains at last output value.
Waveform Name 10 characters maximum  
Waveform Parameters Type: Voltage or current







Positive protection limit:
Vd-c or Ad-c
Negative protection limit:
Vd-c or Ad-c


Count: number

Initial/repeating
Type of waveform, voltage or current, can be selected only for a new wave- form and consequently applies to all waveform segments. Changing the type for an existing waveform is not possible, unless the waveform is erased first.

The Limit values (positive/negative) and the count number apply to all waveform segments and can be edited at the beginning of a new waveform or later when modifying a waveform.

All segments except the last may be set to run once (Initial) or per the count setting (Repeating).
Basic Waveform Parameters Sine: Frequency (Hz), amplitude (Vp-p or Ap-p), offset (Vd-c or Ad-c), start phase (°) , stop phase (°)

Triangular: Frequency (Hz), amplitude (Vp-p or Ap-p), offset (Vdc or Ad-c), start phase (°), stop phase (°)

Ramp (Pos. or Neg.): Frequency (Hz), Amplitude (Vp-p or Ap-p), Offset (Vd-c or Ad-c)

Square: Frequency (Hz), amplitude (Vpg or App), offset (Vck or Adc)

Level: Timing (sec), amplitude (Vp-p or App)

Local (1): The start/stop phases, available for sine and triangle only, can be set or edited by moditylng the existing segment.

Remote: The start/stop phases are global parameters, applicable to all sine and triangular waveform segments.

The start/stop points are independent and can have any value between 0° and 360°.

(1) Local operation applies to -MG and -ME models only.