   BOP 1 KILOWATT PROGRAMMING/DISPLAY CHARACTERISTICS
SPECIFICATION RATING DESCRIPTION
Analog
I/O Port
main channel
voltage or current
-10V to +10V Full range output, 20K Ohm input impedance
protection limit channels
±voltage, ±current
0.05V to +10V O.5% to 100% of nominal range. Input vottage clamped to 12V through 1K Ohms. Maximum of 0.15mA input current at 1V input voltage.
mode control Voltage: open circuit
or TTL logic 1
Current: short circuit
or TTL logic 0
Available only when digitally activated through power-up setting
output current
analog readback
0 to ±10 Volts corresponds to zero to ± full scale nominal output current Output impedance of this signal is 2K Ohms.
External
Protection
I/O Port
external shutdown Isolated input for shutdown of the BOP (latched status) Pulse width: 100 microseconds min.
Action delay: 100 microseconds max.
Restore operation by cycling input power or pressing RESET key(1).
external
shutdown flag
Isolated input indicating shutdown status Action delay: 100 microseconds max.
external on-off flag or external trigger flag: Isolated output indicating output on (enabled, STANDBY off) or off (disabled, STANDBY on) status

Trigger: Isolated trigger output for external devices
Flag: LIST:SET:TRIG enables trigger function
Flag action delay: 200 milliseconds max.

Trigger: LIST:CLE disables trigger and restores flag.
Trigger output pulse duration: settable between 0.25 to 34mS.
Trigger output action delay: 100 microseconds max
Trigger output active level: settable to either 0 or 1.
(1) RESET key applies only to MG and ME models.