BOP 1 KILOWATT FUNCTION GENERATOR CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
Maximum Number
of Waveform
|
Local (1): 16
Remote: 1
|
Local (1): Saved for power-up
Remote: Lost when the unit is turned
off, must be saved on the host computer.
|
Maximum Number
of a) Segments Per Waveform or b) Basic
Waveforms
|
Local (1): 10
Remote: 126 |
Or maximum number of points
(whichever comes first)
The time interval for each segment
depends on the type of waveform:
period for ramp and square waveforms,
period or fraction of period for sine
and triangular waveforms and time
interval for DC levels.
Segments that cause the waveform to
exceed the maximum number of points
are not executed. For local (1) operation
they are marked with a triple asterisk
on the front panel. For remote operating
an error message is generated. |
Type of Basic Waveforms
|
Sine (sinusoidal waveform)
Triangle (triangular waveform)
Pos. Ramp (ramp waveform)
Neg. Ramp (sawtooth waveform)
Square (509.6 duty cycle pulse)
Level (DC waveform)
|
|
Maximum Number of Points
per Basic Waveform
|
Local (1): 3933
|
|