   BOP 1 KILOWATT OUTPUT CHARACTERISTICS (1)
SPECIFICATION RATING/DESCRIPTION CONDITION
MG Models GL Models
Series Operation maximum 3 identical
units
maximum 2 identical
units (2) (3)
master/slave
Parallel Operation maximum 5 identical
units
maximum 2 identical
units (2) (3)
master/slave
Series-Parallel
Operation
2 series x 2 parallel
3 series x 2 parallel
Not available Master/slave for both series and
parallel branches of identical MG units.
Output
Protection
Limiting
Analog Adjustable between 10% and 101%
of EOnom or IOnom
Voltage and
current limited in
four quadrants.
Digital Adjustable between ±Internal minimum
(EOmin. or IOmin.) and ±1.01 EOnom. or IOnom.
Output Stage
Protection
Output overvoltage/overcurrent,
Heatsink overtemperature,
switchers overcurrent
Triggers latched shutdown protection
of the output module and PFC stage.
Recover by cycling power off, then on,
or for MG models, by pressing RESET
at the front panel.
Input Stage
Protection (PFC)
Internal overvoltage, undervoltage,
overcurrent, heat sink overtemperature,
fan inoperative
Input circuit breaker overcurrent Trips circuit breaker to shut off unit.
Small signal
Bandwidth for
main channel
(analog or digital)
Voltage
channel
2 KHz minimum 1 KHz minimum Into nominal resistive load,
10% of rating
Current
channel
800 Hz minimum (4) Into short circuit, 10% of rating
Rise/Fall time Voltage
channel
300/300 µSec 475/475 µSec Into nominal resistive load, measured from
10 to 90%, from 0 to ±100% of rating
Current
channel
500/500 µSec 500/500 µSec Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating
(1) Output characteristics are for a single standalone unit. Output characteristics of identical multiple unit parallel/series configurations are described in the Technical Manual associated with the applicable Cable Kit.
(2) Consult factory to configure more than two units in series or parallel (more than three units in parallel for BOP 10-100GL/EL).
(3) For multiple unit configurations, automatic shutdown upon accidental removal of the cable at the Master PAR/SER IN PROTECT PORT can be implemented with a simple internal modification. Consult factory for details.
(4) 600 Hz minimum for BOP 6-125MG/ME.