Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   BOP 1 KILOWATT OUTPUT CHARACTERISTICS (1)
SPECIFICATION RATING/DESCRIPTION CONDITION
MG Models GL Models
Digital
Readback
Characteristics
Measurement Rate 5 mS  
Measurement Array 64 samples Voltage and current
Rejection of line-
related ripple/noise
50, 60 or 125Hz Digital readback
Voltage
stabilization
in Voltage
Mode
Source Effect 0.05% of rating 0.01% of rating min-max input voltage,
230V a-c reference
Load Effect 0.1% of rating 0.02% of rating 0 - 100% load current
Time Effect (drift) 0.02% of rating 0.01% of rating 0.5 - 8 hours
Temperature Effect 0.02%/°C of rating 0.005%/°C of rating 0 - 50°C
Ripple/Noise (2% EOmax) p-p (2) (5)/
(0.2% EOmax) rms
0.03% of rating (5)
(rms)
 
Current
stabilization
in Current
Mode
Source Effect 0.05% of rating 0.01% of rating min-max input voltage,
230V a-c reference
Load Effect 0.2% of rating 0.02% of rating 0 - 100% load current
Time Effect (drift) 0.02% of rating 0.01% of rating 0.5 - 8 hours
Temperature Effect 0.02%/°C of rating 0.005%/°C of rating 0 - 50°C
Ripple/Noise (2% IOmax) p-p (2) (6)/
(0.2% IOmax) rms
0.01% of rating (6)
(rms)
 
Error Sensing 0.25V or 1% of voltage rating per
wire (whichever is less)
Above rated output voltage (3)
Transient
Recovery
in Voltage
Mode
Maximum
excursion
5% of nominal output nominal voltage,
50% load step
Recovery Time 200 μSec Return within 0.1%
of set voltage
Output
Isolation
Voltage
d-c or p-p 300V
(500V for 10V models)
Output to chassis ground
d-c leakage current 0.1mA @ 300V
(0.1mA @ 500V for 10V -MG and -GL models)
GND-NET to GND link not installed. (4)
(1) Output characteristics are for a single standalone unit.
(2) Includes switching noise.
(3) Remote error sensing applies to the main voltage channel. Feedback for the ±voltage limit channels is supplied locally from the power terminals. Consult factory for a remote sensing solution applicable to the voltage limit channels.
(4) With GND-NET to GND link installed: 0.55mA at 300V (0.91mA at 500V for 10V -MG and -GL models).
(5) Full scale, nominal resistive load.
(6) Full scale, load is shunt only.

PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com