NOTES:
|
(1) |
Actual output voltage should be ≤0.1% of rated voltage when output voltage is set to zero.
|
(2) |
Actual output current should be ≤0.1% of the rated current when output current is set to zero (resistive load).
|
(3) |
Measured when output is within 10%-100% of rated value; ripple bandwidth: 300kHz (rms), noise bandwidth: <20MHz (p-p). |
(4) |
For 6V model: measured when output voltage 2-6V at rated current; all other models measured when output 10-100% of rated voltage and rated current.
|
(5) |
Input voltage 100-240VAC, 50/60Hz. |
(6) |
Constant input voltage and output from 10% of loading to full load. |
(7) |
Rated input, resistive load.
|
(8) |
Rated power output with input 115V or 230V a-c. |
(9) |
Specifications met after 30 minutes of operation, ambient temperature 23±5°C, humidity under 80% R. H, a-c input voltage ±5% of nominal, THD is 2%, not using the remote compensation, not operating in series or parallel. |
(10) |
- Add G suffix for models with optional GPIB interface.
- Add E suffix for optional LAN interface.
- Add C suffix for conformal coating
- See KIT 219-0608 to retrofit LAN interface into non-E suffix models.
|
(11) |
For example, the spec for KLN 6-100 line regulation and load regulation in CV mode is 0.05% + 2.8mV
(or 6 x 0.0005) = ±3mV +2.8mV = 5.8mV, so line and load regulation are within 0.2mV to 5.8mV for 6V model.
|