MODEL
(8) (9) (10)
d-c Output Range Ripple (3) Line Regulation(5) (11) Load Regulation(11) Response Time(7) Remote
Sense
Voltage
Drop
(max)
(V)
CV (1)
(V d-c)
CC (2)
(A d-c)
CV
(mV rms)
CC (4)
(mA rms)
CV
(0.05%
+mV)
CC
(0.1%
+mA)
CV(6)
(0.05%
+mV)
CC(6)
(0.1%
+mA)
Full
Load
Up
(Sec)
Full
Load
Down
(Sec)
No
Load
Down
(Sec)
KLN 6-200 0-6 0-200 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1
KLN 8-180 0-8 0-180 15 360 2.8 18.5 2.8 38 0.08 0.05 0.6 1
KLN 12.5-120 0-12.5 0-120 15 248 3.4 14.5 4 28 0.08 0.05 0.8 1
KLN 20-76 0-20 0-76 15 152 4 9.6 4 20.2 0.08 0.05 0.8 1
KLN 30-50 0-30 0-50 15 125 5 7 5 15 0.08 0.08 0.9 1.5
KLN 40-38 0-40 0-38 15 95 6 5.8 6 12.6 0.08 0.08 1 2
KLN 50-30 0-50 0-30 15 85 7 5.2 7 11.4 0.08 0.08 1.1 2
KLN 60-25 0-60 0-25 15 75 8 4.5 8 10 0.08 0.08 1.1 3
KLN 80-19 0-80 0-19 15 57 10 3.9 10 8.8 0.15 0.15 1.2 4
KLN 100-15 0-100 0-15 15 45 12 3.5 12 8 0.15 0.15 1.5 5
KLN 150-10 0-150 0-10 24 45 12 3.5 12 8 0.15 0.15 2 5
KLN 300-5 0-300 0-5 38 25 32 2.5 32 6 0.15 0.15 3 5
KLN 600-2.5 0-600 0-2.5 113 15 62 2.26 62 5.5 0.25 0.3 4 5
NOTES:
(1) Actual output voltage should be ≤0.1% of rated voltage when output voltage is set to zero.
(2) Actual output current should be ≤0.1% of the rated current when output current is set to zero (resistive load).
(3) Measured when output is within 10%-100% of rated value; ripple bandwidth: 300kHz (rms), noise bandwidth: <20MHz (p-p).
(4) For 6V model: measured when output voltage 2-6V at rated current; all other models measured when output 10-100% of rated voltage and rated current.
(5) Input voltage 190-240VAC, 50/60Hz.
(6) Constant input voltage and output from 10% of loading to full load.
(7) Rated input, resistive load.
(8) Rated power output with input 230V a-c.
(9) Specifications met after 30 minutes of operation, ambient temperature 23±5°C, humidity under 80% R. H, a-c input voltage ±5% of nominal, THD is 2%, not using the remote compensation, not operating in series or parallel.
(10) Add G suffix for models with optional GPIB interface, add E suffix for optional LAN interface. See KIT 219-0608 to retrofit LAN interface into non-E suffix models.