KLN SERIES PROGRAMMING CHARACTERISTICS
LOCAL: 750W, 1500W, 3000W
|
Specification
|
Rating/Description
|
Local control
|
|
Rotary encoder
|
Setting Resolution (Voltage and Current)
|
4 digits
|
Display Resolution (Voltage and Current)
|
4 digits
|
Programming Accuracy
|
Voltage:
|
±0.1% ± 3C(1) at rated voltage
|
Current:
|
±0.5% ± 3C(1) at rated current
|
Display Accuracy
|
Voltage:
|
±0.2% ± 3C(1) at rated voltage
|
Current:
|
±0.5% ± 3C(1) at rated current
|
Overvoltage Protection (OVP)
|
Programmable, 10 to 110% of rated voltage
|
Overcurrent Protection (OCP)
|
Programmable, 10 to 110% of rated current
|