   KLN SERIES PROGRAMMING CHARACTERISTICS
   LOCAL: 750W, 1500W, 3000W
Specification Rating/Description
Local control   Rotary encoder
Setting Resolution (Voltage and Current) 4 digits
Display Resolution (Voltage and Current) 4 digits
Programming Accuracy Voltage: ±0.1% ± 3C(1) at rated voltage
Current: ±0.5% ± 3C(1) at rated current
Display Accuracy Voltage: ±0.2% ± 3C(1) at rated voltage
Current: ±0.5% ± 3C(1) at rated current
Overvoltage Protection (OVP) Programmable, 10 to 110% of rated voltage
Overcurrent Protection (OCP) Programmable, 10 to 110% of rated current

(1) C = 1 count of the last displayed digit.