   KLN SERIES PROGRAMMING CHARACTERISTICS:
   DIGITAL: 750W, 1500W, 3000W
Specification Rating/Description
Command Setting resolution ±0.002% of full scale
Command Readback resolution ±0.002% of full scale
Command and D/A setting accuracy Voltage: ±0.1% ± 3C(1) at rated voltage
Current: ±0.5% ± 3C(1) at rated current
Command and A/D measurement accuracy Voltage: ±0.2% ± 2C(1) at rated voltage (Average Measurement)
Current: ±0.5% ± 3C(1) at rated current (average measurement)
Command Response Time ≤20mS (after received)(2)
RS 485 digital interface
(standard)
Default baud rate: 115.2K, Max baud rate: 115.2K
Max number of units connected to bus: 254
Max effective control distance: 1000 meters
GPIB IEEE 488.2 digital interface Optional (G suffix)
LAN digital interface Optional (E suffix)

NOTES:
(1) C = 1 count of the last displayed digit.
(2) Programming time = Command response time + Output response time. The output response time differs for different models, from 30mS ~ 200mS.