KLN SERIES PROGRAMMING CHARACTERISTICS:
DIGITAL: 750W, 1500W, 3000W
|
Specification
|
Rating/Description
|
Command Setting resolution
|
±0.002% of full scale
|
Command Readback resolution
|
±0.002% of full scale
|
Command and D/A setting accuracy
|
Voltage:
|
±0.1% ± 3C(1) at rated voltage
|
Current:
|
±0.5% ± 3C(1) at rated current
|
Command and A/D measurement accuracy
|
Voltage:
|
±0.2% ± 2C(1) at rated voltage (Average Measurement)
|
Current:
|
±0.5% ± 3C(1) at rated current (average measurement)
|
Command Response Time
|
≤20mS (after received)(2)
|
RS 485 digital interface (standard)
|
Default baud rate: 115.2K, Max baud rate: 115.2K
Max number of units connected to bus: 254
Max effective control distance: 1000 meters
|
GPIB IEEE 488.2 digital interface
|
Optional (G suffix)
|
LAN digital interface
|
Optional (E suffix)
|