   KLN SERIES PROGRAMMING CHARACTERISTICS:
   LOCAL: 5KW, 10KW, 15KW
Specification Rating/Description
Local control   Separate Voltage and Current encoders, touch screen
Setting Resolution (Voltage,
Current and Power)
5 digits
Display Resolution (Voltage,
Current and Power)
5 digits
Programming Accuracy Voltage: ±0.1% of rated voltage + 2 digits
Current: ±0.2% of rated current + 2 digits
Power: ±0.1% of rated power + 2 digits
Display Accuracy Voltage: ±0.1% of rated voltage + 2 digits
Power: ±0.2% of rated power + 2 digits
Current: ±0.2% of rated current + 2 digits
Overvoltage Protection (OVP) Programmable, 0 to 110% of rated output voltage
Overcurrent Protection (OCP) Programmable, 0 to 110% of rated output current
Overpower Protection (OPP) Programmable, 0 to 110% of rated output power