   KLN 3000W MODEL TABLE
MODEL
(8) (9) (10)
d-c Output Range Ripple (3) Line Regulation(5) (11) Load Regulation(11) Response Time(7) Remote
Sense
Voltage
Drop
(max)
(V)
CV (1)
(V d-c)
CC (2)
(A d-c)
CV
(mV rms)
CC (4)
(mA rms)
CV
(0.05%
+mV)
CC
(0.1%
+mA)
CV(6)
(0.05%
+mV)
CC(6)
(0.1%
+mA)
Full
Load
Up
(Sec)
Full
Load
Down
(Sec)
No
Load
Down
(Sec)
KLN 6-400 0-6 0-400 23 1000 2.8 42 6.2 85 0.08 0.02 0.5 1
KLN 8-360 0-8 0-360 23 1000 2.8 42 6.2 85 0.08 0.02 0.5 1
KLN 12.5-240 0-12.5 0-240 23 800 3.2 29 7.1 60 0.08 0.1 0.8 1
KLN 20-150 0-20 0-150 23 600 4 18.5 8 38 0.08 0.1 0.8 1
KLN 30-100 0-30 0-100 23 310 5 13 9.5 27 0.08 0.16 0.9 1.5
KLN 40-76 0-40 0-76 23 250 6 10.5 11 22 0.08 0.16 1 2
KLN 50-60 0-50 0-60 23 200 7 9 13 19 0.08 0.16 1.1 2
KLN 60-50 0-60 0-50 23 150 8 7.5 14 16 0.08 0.16 1.1 3
KLN 80-38 0-80 0-38 23 110 10 6.2 17 13.4 0.15 0.3 1.2 4
KLN 100-30 0-100 0-30 23 90 12 5.3 20 11.6 0.15 0.3 1.5 5
KLN 150-20 0-150 0-20 36 90 17 4.2 27.5 9.4 0.15 0.3 2 5
KLN 300-10 0-300 0-10 57 50 32 3.1 50 7.2 0.15 0.3 3.5 5
KLN 600-5 0-600 0-5 170 30 62 2.55 95 6.1 0.25 0.5 4 5
NOTES:
(1) Actual output voltage should be ≤0.1% of rated voltage when output voltage is set to zero.
(2) Actual output current should be ≤0.1% of the rated current when output current is set to zero (resistive load).
(3) Measured when output is within 10%-100% of rated value; ripple bandwidth: 300kHz (rms), noise bandwidth: <20MHz (p-p).
(4) For 6V model: measured when output voltage 2-6V at rated current; all other models measured when output 10-100% of rated voltage and rated current.
(5) Input voltage 190-240VAC, 50/60Hz.
(6) Constant input voltage and output from 10% of loading to full load.
(7) Rated input, resistive load.
(8) Rated power output with input 230V a-c.
(9) Specifications met after 30 minutes of operation, ambient temperature 23±5°C, humidity under 80% R. H, a-c input voltage ±5% of nominal, THD is 2%, not using the remote compensation, not operating in series or parallel.
(10) Add G suffix for models with optional GPIB interface, add E suffix for optional LAN interface. See KIT 219-0608 to retrofit LAN interface into non-E suffix models.
(11) For example, the spec for KLN 6-400 line regulation and load regulation in CV mode is 0.05% + 6.2mV (or 6 x 0.0005) = ±3mV +6.2mV = 9.2mV, so line and load regulation are within 0.2mV to 9.2mV for 6V model.
PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com