KLN 15kW EXTENDED RANGE MODEL TABLE
|
MODEL (1)
|
Max Power
|
Rated Voltage (Volts)
|
Maximum Current (Amperes) for Rated Voltage
|
Rated Current (Amperes)
|
Maximum Voltage (Volts) for Rated Current
|
Ripple and Noise
|
Internal Resistance Range (Ohms)
|
|
(V1) (2)
|
(A1) (2)
|
(A2) (2)
|
(V2) (2)
|
CV (mV rms)
|
CC (mA rms)
|
KLN 80-540E |
15kW |
0 - 80 |
187.5 |
0 - 540 |
27.78 |
25 |
255 |
0 ~ 0.148 |
KLN 250-180E |
15kW |
0 - 250 |
60 |
0 - 180 |
83.33 |
50 |
57 |
0 ~ 1.390 |
KLN 350-126E |
15kW |
0 - 350 |
42.84 |
0 - 126 |
119.05 |
60 |
51 |
0 ~ 2.780 |
KLN 500-90E |
15kW |
0 - 500 |
30 |
0 - 90 |
166.67 |
70 |
48 |
0 ~ 5.560 |
KLN 650-69E |
15kW |
0 - 650 |
23.07 |
0 - 69 |
217.39 |
170 |
48 |
0 ~ 9.420 |
KLN 1050-42E |
15kW |
0 - 1050 |
14.29 |
0 - 42 |
357.14 |
350 |
35 |
0 ~ 25.00 |
KLN 1500-30E |
15kW |
0 - 1500 |
10 |
0 - 30 |
500 |
400 |
26 |
0 ~ 50.00 |
KLN 1950-23E |
15kW |
0 - 1950 |
7.69 |
0 - 23 |
650 |
400 |
26 |
0 ~ 84.78 |
NOTES:
|
(1) |
For the 15kW KLN Extended Range Series each Model number KLN [ V ] - [ C ] [ X ] describes Rated Voltage, Rated Current and Interface where
V = Rated Voltage in Volts,
C = Rated Current in Amperes,
X = Interface(s) included, where
E = LAN (LXI) standard on all models
G = LAN (LXI) plus optional GPIB
U = LAN (LXI) plus optional USB
S = LAN (LXI) plus optional Serial Port (RS 422/RS 485)
A = LAN (LXI) plus optional Isolated Analog
As an example, KLN 80-540E is a 15kW model with Rated Voltage = 80V, Rated Current = 540A and LAN (LXI) interface.
|
(2) |
Referring to the figure above, a conventional output power range would require three power supplies to meet the following requirements:
V x A = Rated Power, V1 x A1 = Rated Power, V2 x A2 = Rated Power
The constant power technique used by the KLN Extended Range Series allows a single power supply to meet the three requirements noted above for V x A, V1 x A1 and V2 x A2, plus all points within the area beneath the arc formed by "A", "B" and "C". This is possible because the maximum voltage and current are not fixed, but are limited by the maximum power of the KLN Extended Range power supply.
|
|