Kepco's BOP bipolar power supplies are fully controllable via either GPIB or RS 232 protocols by means of a factory-installed BIT 4886 card which is 16-bit with resolution of 1/216. The BOP/BIT 4886 combination offers Talk-listen support for the IEEE 488.2 bus using SCPI commands/queries.
The BOP communicates as a stand-alone instrument, directly on the GPIB. The BOP can also be programmed over the RS232C bus using either SCPI or CIIL commands via either an RS232-C terminal, or from a PC using a terminal emulation program with a baud rate of 9600, no parity, eight data bits and one stop bit. A downloadable driver supports digital calibration (no manual pots) and multiple control and read back ranges which are
incorporated into the digital interface. See detailed specifications for the BOP with the BIT 4886 card installed.
NOTE: The BOP with GPIB/RS 232 control is compatible with National Instruments standard 488-HS.
When connecting BOP with BIT 4886 cards installed in parallel or series, the slave BIT card must be disabled; refer to refer to BOP Application Note: How to Disable BIT card in BOP models with BIT 802E or 4886 cards installed or in BOP 2X-DE Models for instructions as well as how to maintain digital control over a parallel/series combination.
|
Model BOP 50-2D-4886 (top), Model BOP 100-4D-4886 (bottom)
|
100W BOP-4886 Series: GPIB or RS 232 Control
True 4-quadrant programmable voltage and current GPIB or RS 232 control power supplies.
3 Standard Models:
0 to ±20 Volts, 0 to ±5 Amps,
0 to 50 Volts, 0 to 2 Amps,
0 to 100 Volts, 0 to 1 Amp,
Stand-alone instrument, direct communication on GPIB.
Can be programmed over RS232C bus using either
SCPI or CIIL commands: either via RS232-C terminal,
or from a PC using a terminal emulation program
Downloadable driver supports digital calibration.
Multiple control and read back ranges.
Compatible with National Instruments standard 488-HS.
|
100W BOP-4886 (GPIB and RS 232 control) Analog Meter Models
0 to ±20V, 0 to ±5A: |
BOP 20-5M-4886 |
0 to ±50V, 0 to ±2A: |
BOP 50-2M-4886 |
0 to ±100V, 0 to ±1A: |
BOP 100-1M-4886 |
100W BOP-4886 (GPIB and RS 232 control) Digital Meter Models
0 to ±20V, 0 to ±5A: |
BOP 20-5D-4886 |
0 to ±50V, 0 to ±2A: |
BOP 50-2D-4886 |
0 to ±100V, 0 to ±1A: |
BOP 100-1D-4886 |
|
200W BOP-4886 Series: GPIB or RS 232 Control
True 4-quadrant programmable voltage and current GPIB or RS 232 control power supplies.
5 Standard Models:
0 to ±20 Volts, 0 to ±10 Amps,
0 to ±36 Volts, 0 to ±6 Amps,
0 to ±50 Volts, 0 to ±4 Amps,
0 to ±100 Volts, 0 to ±2 Amps,
0 to ±200 Volts, 0 to ±1 Amp,
Stand-alone instrument, direct communication on GPIB.
Can be programmed over RS232C bus using either
SCPI or CIIL commands: either via RS232-C terminal,
or from a PC using a terminal emulation program
Downloadable driver supports digital calibration.
Multiple control and read back ranges.
Compatible with National Instruments standard 488-HS.
|
200W BOP-4886 (GPIB and RS 232 control) Analog Meter Models
0 to ±20V, 0 to ±10A: |
BOP 20-10M-4886 |
0 to ±36V, 0 to ±6A: |
BOP 36-6M-4886 |
0 to ±50V, 0 to ±4A: |
BOP 50-4M-4886 |
0 to ±100V, 0 to ±2A: |
BOP 100-2M-4886 |
0 to ±200V, 0 to ±1A: |
BOP 200-1M-4886 |
200W BOP-4886 (GPIB and RS 232 control) Digital Meter Models
0 to ±20V, 0 to ±10A: |
BOP 20-10D-4886 |
0 to ±36V, 0 to ±6A: |
BOP 36-6D-4886 |
0 to ±50V, 0 to ±4A: |
BOP 50-4D-4886 |
0 to ±100V, 0 to ±2A: |
BOP 100-2D-4886 |
0 to ±200V, 0 to ±1A: |
BOP 200-1D-4886 |
|
400W BOP-4886 Series: GPIB or RS 232 Control
True 4-quadrant programmable voltage and current GPIB or RS 232 control power supplies.
5 Standard Models:
0 to ±20 Volts, 0 to ±20 Amps,
0 to ±36 Volts, 0 to ±12 Amps,
0 to ±50 Volts, 0 to ±8 Amps,
0 to ±72 Volts, 0 to ±6 Amps,
0 to ±100 Volts, 0 to ±4 Amps,
Stand-alone instrument, direct communication on GPIB.
Can be programmed over RS232C bus using either
SCPI or CIIL commands: either via RS232-C terminal,
or from a PC using a terminal emulation program
Downloadable driver supports digital calibration.
Multiple control and read back ranges.
Compatible with National Instruments standard 488-HS.
|
400W BOP-4886 (GPIB and RS 232 control) Analog Meter Models
0 to ±20V, 0 to ±20A: |
BOP 20-20M-4886 |
0 to ±36V, 0 to ±12A: |
BOP 36-12M-4886 |
0 to ±50V, 0 to ±8A: |
BOP 50-8M-4886 |
0 to ±72V, 0 to ±6A: |
BOP 72-6M-4886 |
0 to ±100V, 0 to ±4A: |
BOP 100-4M-4886 |
400W BOP-4886 (GPIB and RS 232 control) Digital Meter Models
0 to ±20V, 0 to ±20A: |
BOP 20-20D-4886 |
0 to ±36V, 0 to ±12A: |
BOP 36-12D-4886 |
0 to ±50V, 0 to ±8A: |
BOP 50-8D-4886 |
0 to ±72V, 0 to ±6A: |
BOP 72-6D-4886 |
0 to ±100V, 0 to ±4A: |
BOP 100-4D-4886 |
|
|