   BOP DYNAMIC SPECIFICATIONS
MODEL (1) (7) BANDWIDTH (2) (3)
(d-c to f-3dB)
KHz (minimum)
Mode
RISE & FALL TIME (2) (4)
10% to 90%
μsec (minimum)
Mode
LARGE SIGNAL
FREQUENCY
RESPONSE
KHz (minimum)
Mode
SLEWING RATE (2) (5)
(mimumum)
Mode
RECOVERY (2) (6)
STEP LOAD
μsec (minimum)
Mode
V I V I V I V I V I
100 WATT
BOP 5-20 22 11 17 32 11 3.9 0.47V/μsec 1.0A/μsec 40 100
BOP 20-5 18 12 20 30 17 13 1.6V/μsec 0.27A/μsec 25 10
BOP 50-2 18 12 20 35 17 13 4.0V/μsec 0.11A/μsec 25 10
BOP 100-1 18 11 22 25 18 11 9.4V/μsec 0.07A/μsec 40 25
200 WATT
BOP 5-30 12 9 30 40 11 3.5 0.27V/μsec 1.2A/μsec 50 60
BOP 20-10 18 10 20 40 17 7 1.6V/μsec 0.27A/μsec 80 20
BOP 36-6 16 13 25 30 15 14 2.5V/μsec 0.61A/μsec 50 35
BOP 50-4 23 14 15 25 15 11 5.7V/μsec 0.26A/μsec 40 30
BOP 72-3 20 15 18 26 17 12 6.4V/μsec 0.18A/μsec 30 30
BOP 100-2 22 15 18 26 17 12 8.9V/μsec 0.12A/μsec 30 30
BOP 200-1 4.0 2.5 110 150 4.0 2.5 2.9V/μsec 0.01A/μsec 150 120
400 WATT
BOP 20-20 9.5 10 35 35 8 10 0.9V/μsec 0.91A/μsec 100 75
BOP 36-12 20 10 16 35 19 10 3.6V/μsec 0.64A/μsec 50 30
BOP 50-8 24 10 14 35 24 11 5.7V/μsec 0.37A/μsec 40 30
BOP 72-6M 19 9.5 18 40 20 11 6.4V/μsec 0.24A/μsec 50 20
BOP 100-4 18 14 22 30 16 10 7.3V/μsec 0.21A/μsec 40 30
NOTES:
(1) Models with analog meters include suffix M; models with digital meters include suffix D.
(2) Specifications listed are for Input @ 115V, 60Hz.
(3) Represents 3-dB bandwidth for large sine signal for nominal resistive load/peak output voltage value @ 50Hz, equal to EOmax in V mode and for short circuit/peak output current @ 50Hz, equal to IOmax in I mode.
(4) Represents the response timing of the pulsed output (@ 100Hz) for nominal resistive load/between ±EOmax in V mode and for short circuit/between ± IOmax in I mode.
(5) Defined as the ratio between (1.6)(EOmax) or (1.6)(IOmax) and the corresponding rise/fall time for the same conditions described in Note (4) above.
(6) Represents the 10-90% timing of a changing output when the load is switched between no load and nominal resistive load in V mode and between short circuit and nominal resistive load in I mode.
(7) Dynamic specifications are for models with either M or D suffix. For models with L or C options (ML, MC, DL or DC suffix) see applicable Modification Sheets.