Kepco's new BOP-E Series of Ethernet-controlled 100W, 200W and 400W BOP linear bipolar power supplies deliver fast, ultra quiet and clean bipolar power. Kepco's BOP-E's models can be controlled from anywhere over Ethernet or LAN. Communication is either through a web page or by using SCPI commands via LabView and Telnet.
- True 4-quadrant programmable voltage and current power supplies.
- 14 Standard Models, ± 0-5 Volts to ± 0-200 Volts, ± 0-5 Amps to ± 0-30 Amps.
- Dual-range, 16-bit interface provides 15 bits of resolution for both full and quarter scale of output.
- Inductive load and capacitive load optimized versions.
- Discovery: MDNS (Bonjour - like the printer discovery) and VXI-11 (National Instruments Ni Max, Agilent Io controller)
- IP address support: DCHP, AUTOIP and Static IP (using Web Page)
- Connections: SOCKET @ port 5025 and TELNET @ port 5024
- Connection throughput: 25 milliseconds
- EPICS Driver (Linux compatible) now available!
The BOP-E Series are the latest additions to Kepco's family of ethernet-controlled power supplies and electronic loads.
When connecting BOP with BIT 802E cards installed in parallel or series, the slave BIT card must be disabled; refer to refer to BOP Application Note: How to Disable BIT card in BOP models with BIT 802E or 4886 cards installed or in BOP 2X-DE Models for instructions as well as how to maintain digital control over a parallel/series combination.
|
Model BOP 50-2D-802E (top), Model BOP 100-4D-802E (bottom)
|
100W BOP-E Series (Ethernet Control)
True 4-quadrant programmable voltage and current ethernet control power supplies.
3 Standard Models:
0 to ±20 Volts, 0 to ±5 Amps,
0 to 50 Volts, 0 to 2 Amps,
0 to 100 Volts, 0 to 1 Amp,
Dual-range, 16-bit interface provides 15 bits of resolution
for both full and quarter scale of output.
Inductive and capacitive load optimized versions.
Discovery: MDNS (Bonjour - like the printer discovery)
and VXI-11 (National Instruments Ni Max, Agilent Io
controller)
IP address support: DCHP, AUTOIP and Static IP
(using Web Page)
Connections: SOCKET @ port 5025 and
TELNET @ port 5024
Connection throughput: 25 milliseconds
|
100W BOP-E Analog Meter Models
0 to ±20V, 0 to ±5A: |
BOP 20-5M-802E |
0 to ±50V, 0 to ±2A: |
BOP 50-2M-802E |
0 to ±100V, 0 to ±1A: |
BOP 100-1M-802E |
100W BOP-E Digital Meter Models
0 to ±5V, 0 to ±20A: |
BOP 5-20D-802E |
0 to ±20V, 0 to ±5A: |
BOP 20-5D-802E |
0 to ±50V, 0 to ±2A: |
BOP 50-2D-802E |
0 to ±100V, 0 to ±1A: |
BOP 100-1D-802E |
|
200W BOP-E Series (Ethernet Control)
True 4-quadrant programmable voltage and current ethernet control power supplies.
5 Standard Models:
0 to ±20 Volts, 0 to ±10 Amps,
0 to ±36 Volts, 0 to ±6 Amps,
0 to ±50 Volts, 0 to ±4 Amps,
0 to ±100 Volts, 0 to ±2 Amps,
0 to ±200 Volts, 0 to ±1 Amp,
Dual-range, 16-bit interface provides 15 bits of resolution
for both full and quarter scale of output.
Inductive and capacitive load optimized versions.
Discovery: MDNS (Bonjour - like the printer discovery)
and VXI-11 (National Instruments Ni Max, Agilent Io
controller)
IP address support: DCHP, AUTOIP and Static IP
(using Web Page)
Connections: SOCKET @ port 5025 and
TELNET @ port 5024
Connection throughput: 25 milliseconds
|
200W BOP-E Analog Meter Models
0 to ±20V, 0 to ±10A: |
BOP 20-10M-802E |
0 to ±36V, 0 to ±6A: |
BOP 36-6M-802E |
0 to ±50V, 0 to ±4A: |
BOP 50-4M-802E |
0 to ±100V, 0 to ±2A: |
BOP 100-2M-802E |
0 to ±200V, 0 to ±1A: |
BOP 200-1M-802E |
200W BOP-E Digital Meter Models
0 to ±20V, 0 to ±10A: |
BOP 20-10D-802E |
0 to ±36V, 0 to ±6A: |
BOP 36-6D-802E |
0 to ±50V, 0 to ±4A: |
BOP 50-4D-802E |
0 to ±100V, 0 to ±2A: |
BOP 100-2D-802E |
0 to ±200V, 0 to ±1A: |
BOP 200-1D-802E |
|
400W BOP-E Series (Ethernet Control)
True 4-quadrant programmable voltage and current ethernet control power supplies.
5 Standard Models:
0 to ±20 Volts, 0 to ±20 Amps,
0 to ±36 Volts, 0 to ±12 Amps,
0 to ±50 Volts, 0 to ±8 Amps,
0 to ±72 Volts, 0 to ±6 Amps,
0 to ±100 Volts, 0 to ±4 Amps,
Dual-range, 16-bit interface provides 15 bits of resolution
for both full and quarter scale of output.
Inductive and capacitive load optimized versions.
Discovery: MDNS (Bonjour - like the printer discovery)
and VXI-11 (National Instruments Ni Max, Agilent Io
controller)
IP address support: DCHP, AUTOIP and Static IP
(using Web Page)
Connections: SOCKET @ port 5025 and
TELNET @ port 5024
Connection throughput: 25 milliseconds
|
400W BOP-E Analog Meter Models
0 to ±20V, 0 to ±20A: |
BOP 20-20M-802E |
0 to ±36V, 0 to ±12A: |
BOP 36-12M-802E |
0 to ±50V, 0 to ±8A: |
BOP 50-8M-802E |
0 to ±72V, 0 to ±6A: |
BOP 72-6M-802E |
0 to ±100V, 0 to ±4A: |
BOP 100-4M-802E |
400W BOP-E Digital Meter Models
0 to ±20V, 0 to ±20A: |
BOP 20-20D-802E |
0 to ±36V, 0 to ±12A: |
BOP 36-12D-802E |
0 to ±50V, 0 to ±8A: |
BOP 50-8D-802E |
0 to ±72V, 0 to ±6A: |
BOP 72-6D-802E |
0 to ±100V, 0 to ±4A: |
BOP 100-4D-802E |
|
|