   KLR PROGRAMMING CHARACTERISTICS (DIGITAL)
Specification Rating/Description Condition
Supported
Interfaces
standard models: GPIB and RS 232 Support SCPI command set for GPIB and RS 232
E-Series models: GPIB and LAN
Support four interfaces for LAN:
   1. Web interface, port 80
   2. SCPI Telnet, port 5024
   3. SCPI Sockets, port 5025
   4. VXI 11, port 1024
Support SCPI command set for GPIB and LAN;
GPIB GPIB address range: 1 to 30 Factory default is 6.
RS 232 standard models only: Baud Rate range: 2400, 4800, 9600, 19,200 or 38,400 Factory default is 38,400.
Digital
remote
control
isolation: Safety Extra Low Voltage (SELV)  
format: compatible with SCPI protocols W98 SE and later operating systems.
Programming resolution 0.024% of Emax and Imax  
Programming accuracy 0.05% of Emax and Imax  
Readback resolution 0.024% of Emax and Imax  
Readback accuracy 0.1% of Emax and Imax  
Status reporting OVP, OCP, OTP, output lead fault (OLF), fan failure, power loss  