SERIES KLR INPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
Input Voltage |
Nominal: |
200-240 Va-c Single Phase
|
|
Range: |
180-265 Va-c Wide Range
|
Input Frequency |
Nominal range: |
50-60 Hz
|
|
maximum: |
45-440 Hz
|
Increased Leakage above 66 Hz.
|
Input Current
|
Maximum 230V a-c 12Arms
|
Rated load (2400W)
|
Inrush current
|
240V a-c - 40A
|
Maximum instantaneous peak
|
Power Factor (PF)
|
0.99
|
Meets EN 61000-3-2.
|
Input Fusing
|
Circuit Breaker
|
2-line
|
Low arc Protection
|
175V a-c self-protected
|
User
|
Electromagnetic Compatibility |
Emissions: |
CISPR 11, Class A
|
Class B conducted
|
Immunity: |
EN61326-1, Table L
|
Industrial Equipment
|
Leakage Current
|
2.3mA max
|
230 Va-c, 50/60Hz
|
Withstand Voltage |
Input - Chassis: |
2121V d-c (all models)
|
25°C, 65% RH
|
Output - Chassis: |
1250V d-c (20V, 40V models)
2121V d-c (75V, 150V, 300V models)
|
Input - Output: |
2500V d-c (20V, 40V models)
4242V d-c (75V, 150V, 300V models)
|
|