   KLR PROGRAMMING CHARACTERISTICS (ANALOG)
Specification Rating/Description Condition
Analog
remote
control
selection: Activate with jumper at analog programming connector Recognized during power up.
isolation: Safety Extra Low Voltage (SELV)
Analog Input Update Rate 2Hz (0.5 Second) Applies to programming by voltage/ resistance and readback specifications. Analog input voltage digitized (12-bit resolution), optically isolated, then processed by digital section.
Programming
by voltage
voltage: 0-10V Full scale voltage may be reduced below 10V.
current: 0-10V See Model Table for minimum programmable current. Full scale voltage may be reduced below 10V.
Programming
by resistance
voltage: 0-10K ohms Full scale resistance may be reduced below 10K Ohms.
current: 0-10K ohms See Model Table for minimum programmable current. Full scale resistance may be reduced below 10K Ohms.
Readback 0-10V proportional signal Proportional to analog control voltage/resistance.
Remote inhibit TTL compatible Dual polarity
Composite status flag Isolated form C contacts Programmable