KLP PROGRAMMING CHARACTERISTICS (DIGITAL)
|
Specification
|
Rating/Description
|
Condition
|
Supported Interfaces |
standard models: |
GPIB and RS 232
|
Support SCPI command set for GPIB and RS 232 (see KLP Developer's Guide)
|
E-Series models: |
GPIB and LAN
Support four interfaces for LAN:
1. Web interface, port 80
2. SCPI Telnet, port 5024
3. SCPI Sockets, port 5025
4. VXI 11, port 1024
|
Support SCPI command set for GPIB and LAN; (see KLP Developer's Guide)
|
GPIB
|
GPIB address range: 1 to 30
|
Factory default is 6.
|
RS 232 |
standard models only: |
Baud Rate range: 2400, 4800, 9600, 19,200 or 38,400
|
Factory default is 38,400.
|
Digital remote control |
isolation: |
Safety Extra Low Voltage (SELV)
|
|
format: |
compatible with SCPI protocols
|
W98 SE and later operating systems.
|
Programming resolution
|
0.024% of Emax and Imax
|
|
Programming accuracy
|
0.05% of Emax and Imax
|
|
Readback resolution
|
0.024% of Emax and Imax
|
|
Readback accuracy
|
Either 0.1% of Emax and Imax or front panel voltmeter or ammeter display resolution, whichever is greater. (1)
|
±1 LSB
|
Status reporting
|
OVP, OCP, OTP, output lead fault (OLF), fan failure, power loss
|
Detected fault shuts down power supply output. Overvoltage and overcurrent protection values can be individually proogrammed.
|
NOTES:
|
(1) |
Display resolution is determined by the number of significant digits shown, relative to the decimal point. Resolution is 10-X where X is the number of digits to the right of the decimal point. E.g., for display of 10.00V, resolution is 10-2 or 0.01 or 10mV; for display of 150.0A, resolution is 10-1 or 0.1 or 100mA.
|
|