SERIES KLP OUTPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
Type of Stabilizer
|
CV/CC
|
Voltage/Current
|
Adjustment Range |
Voltage: |
0-100% of rated voltage |
No minimum load required. |
Current: |
minimum to 100% of rated current |
No minimum load required. See Model Table for minimum programmable current. |
Source effect |
Voltage: |
0.01% Emax |
Over full source range. |
Current: |
0.01% Imax |
Load effect |
Voltage: |
0.02% Emax |
Over full load range. |
Current: |
0.05% Imax |
Temperature effect |
Voltage: |
0.01%/deg C |
0-50 deg C |
Current: |
0.01%/deg C |
Time effect (drift) |
Voltage: |
0.02%/24hr |
After 30 min warmup. |
Current: |
0.02%/24hr |
Error Sensing
|
0.25 volts per wire
|
Above rated output. Contact factory for larger margins.
|
Isolation Voltage
|
600V d-c or peak
(100V for 10V, 20V and 36V models)
|
Either output terminal to ground.
|
Transient recovery for load change |
Excursion: |
1% of Emax |
50% load step 2A/microsecond max. |
Recovery: |
2 msec |
Return to 0.1% of setting. |
Turnon/turnoff overshoot
|
2%
|
Rated output, any load
|
Rise Time |
Voltage: |
10, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
|
0 - Emax, rated load (resistive) |
Current: |
10, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
|
0 - Imax, rated load (resistive) |
Fall Time |
Voltage, no load: |
10V: 475 msec
20V: 525 msec
36V: 825 msec
75V: 2820 msec
150V: 4850 msec
300V: 4400 msec
600V: 3150 msec
|
Emax - 0, no load (open circuit).
(For improved performance, see RODC option)
|
Voltage, rated load: |
10V, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
|
Emax - 0, rated load (resistive) |
Current: |
10V, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
|
Imax - 0, rated load (resistive) |
Overvoltage protection
|
20-120% of Emax
|
User selectable recovery (1)
|
Overcurrent protection
|
72-120% of Imax
|
User selectable recovery (1)
|
Output lead wire protection
|
Shutdown
|
User selectable recovery (1)
|
Parallel Operation
|
Active load sharing within 5% of IO rated
|
Up to 5 units, maximum.
|