Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   SERIES KLP OUTPUT CHARACTERISTICS
Specification Rating/Description Condition
Type of Stabilizer CV/CC Voltage/Current
Adjustment
Range
Voltage: 0-100% of rated voltage No minimum load required.
Current: minimum to 100%
of rated current
No minimum load required. See Model Table for minimum programmable current.
Source effect Voltage: 0.01% Emax Over full source range.
Current: 0.01% Imax
Load effect Voltage: 0.02% Emax Over full load range.
Current: 0.05% Imax
Temperature
effect
Voltage: 0.01%/deg C 0-50 deg C
Current: 0.01%/deg C
Time effect
(drift)
Voltage: 0.02%/24hr After 30 min warmup.
Current: 0.02%/24hr
Error Sensing 0.25 volts per wire Above rated output. Contact factory for larger margins.
Isolation Voltage 600V d-c or peak
(100V for 10V, 20V and 36V models)
Either output terminal to ground.
Transient
recovery for
load change
Excursion: 1% of Emax 50% load step 2A/microsecond max.
Recovery: 2 msec Return to 0.1% of setting.
Turnon/turnoff
overshoot
2% Rated output, any load
Rise Time Voltage: 10, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
0 - Emax, rated load (resistive)
Current: 10, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
0 - Imax, rated load (resistive)
Fall Time Voltage,
no load:
10V: 475 msec
20V: 525 msec
36V: 825 msec
75V: 2820 msec
150V: 4850 msec
300V: 4400 msec
600V: 3150 msec
Emax - 0, no load (open circuit). (For improved performance, see RODC option)
Voltage,
rated load:
10V, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
Emax - 0, rated load (resistive)
Current: 10V, 20V, 36V: 30 msec
75V: 40 msec
150V: 50 msec
300V: 60 msec
600V: 75 msec
Imax - 0, rated load (resistive)
Overvoltage protection 20-120% of Emax User selectable recovery (1)
Overcurrent protection 72-120% of Imax User selectable recovery (1)
Output lead wire protection Shutdown User selectable recovery (1)
Parallel Operation Active load sharing within
5% of IO rated
Up to 5 units, maximum.
(1) Either PROTECTED (output disabled and locked until source power recycled) or SAFE (output disabled with unit programmed to last setting; power recycling not needed for recovery).

PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com