SERIES KLP INPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
a-c voltage |
Nominal: |
100-240 Va-c Single Phase
|
Single phase
|
Range: |
90-265 Va-c
|
Wide Range
|
Input Frequency |
Nominal range: |
50-60 Hz
|
|
maximum: |
45-440 Hz
|
Increased Leakage above 66 Hz.
|
Power Factor (PF)
|
typical
|
0.99
|
Meets EN 61000-3-2.
|
Maximum Input Current |
120 Va-c: |
13A rms
|
Rated load (1200W)
|
240 Va-c: |
6.5A rms
|
Rated load (1200W)
|
Inrush current |
265 Va-c: |
40A
|
Peak
|
132 Va-c: |
20A
|
Peak
|
Input Fusing
|
Circuit breaker
|
2-line
|
Low a-c protection
|
87V a-c, Self protected
|
|
Output holdup |
typical: |
10 milliseconds
|
Ride through
|
Leakage Current |
115 Va-c, 60 Hz: |
1.2mA max.
|
|
230 Va-c, 50 Hz: |
2.3mA max.
|
|
Electromagnetic compatibility |
Emissions: |
CISPR11, Class A
|
Class B Conducted
|
Immunity: |
EN 61326-1, Table 2
|
Industrial Environment
|
Withstand Voltage |
Input - Chassis: |
2121V d-c (all models)
|
|
Output - Chassis: |
1250V d-c (10V, 20V, 36V models)
2121V d-c (75V, 150V, 300V, 600V models)
|
Input - Output: |
2500V d-c (10V, 20V, 36V models)
4242V d-c (75V, 150V, 300V, 600V models)
|
|