KLP PROGRAMMING CHARACTERISTICS (ANALOG)
|
Specification
|
Rating/Description
|
Condition
|
Analog remote control |
selection: |
Activate with jumper at analog programming connector
|
Recognized during power up.
|
isolation: |
Safety Extra Low Voltage (SELV)
|
|
Analog Input Update Rate
|
2Hz (0.5 Second) Applies to programming by voltage/ resistance and readback specifications.
|
Analog input voltage digitized (12-bit resolution), optically isolated, then processed by digital section.
|
Programming by voltage |
voltage: |
0-10V
|
Voltage equivalent to Full Scale can be reduced by the user.
|
current: |
0-10V
|
See Model Table for minimum programmable current. Voltage equivalent to Full Scale can be reduced by the user.
|
Programming by resistance |
voltage: |
0-10K ohms
|
Resistance equivalent to Full Scale can be reduced by the user.
|
current: |
0-10K ohms
|
See Model Table for minimum programmable current. Resistance equivalent to Full Scale can be reduced by the user.
|
Readback
|
0-10V proportional signal
|
Proportional to analog control voltage/resistance.
|
Remote inhibit
|
TTL compatible
|
Dual polarity, can be active (inhibit the output) for either a TTL high or low)
|
Composite status flag
|
Isolated form C contacts
|
Programmable. Flags either a) system fault, b) transition from CV to CC mode or c) transition from CC to CV mode.
|