   KLP PROGRAMMING CHARACTERISTICS (ANALOG)
Specification Rating/Description Condition
Analog
remote
control
selection: Activate with jumper at analog programming connector Recognized during power up.
isolation: Safety Extra Low Voltage (SELV)  
Analog Input
Update Rate
2Hz (0.5 Second) Applies to programming by voltage/ resistance and readback specifications. Analog input voltage digitized (12-bit resolution), optically isolated, then processed by digital section.
Programming
by voltage
voltage: 0-10V Voltage equivalent to Full Scale can be reduced by the user.
current: 0-10V See Model Table for minimum programmable current. Voltage equivalent to Full Scale can be reduced by the user.
Programming
by resistance
voltage: 0-10K ohms Resistance equivalent to Full Scale can be reduced by the user.
current: 0-10K ohms See Model Table for minimum programmable current. Resistance equivalent to Full Scale can be reduced by the user.
Readback 0-10V proportional signal Proportional to analog control voltage/resistance.
Remote inhibit TTL compatible Dual polarity, can be active (inhibit the output) for either a TTL high or low)
Composite status flag Isolated form C contacts Programmable. Flags either a) system fault, b) transition from CV to CC mode or c) transition from CC to CV mode.

PREVIOUS TOP NEXT