   SERIES HSP SIGNALS AND FLAGS
Specification Rating/Description Condition
Status Flags
(Form C dry
relay contacts) (1)
POWER: Indicates low source voltage; signal asserted 5msec prior to loss of output voltage. Both NO and NC contacts available.
OUTPUT: Indicates normal operation
OVERTEMP: Overtemperature shutdown
FAN FAIL: Failure of internal fan
Status Indicators,
front panel LEDs (1)
POWER: Green Lit when a-c is sufficient.
DC FAIL: Red Lit when output failure is detected.
OVER TEMP: Yellow Lit when thermostat operates.
FAN FAIL: Red Lit when fan failure is detected.
Test Point,
Setpoint Monitor
Voltage: 0.1 x EOUT  
Current: 0 - 5V full scale
Auxiliary Voltage
(isolated)
4.5 - 5.5V d-c isolated
0 - 100 milliamperes
Present whenever housekeeping supply is operating.
(1) Status indicators and status flags are isolated and operate independently although driven by the same detector circuit.