Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   SERIES HSP CONTROL
Specification Rating/Description Condition
Voltage set
programming
(mode selected
by internal
switches)
(isolated)
Internal: Multiturn potentiometer The DC OK /DC FAIL fault window tracks the programmed output voltage, OVP trip unaffected.
External 1: Resistance:
0- 10K Ohms = 100 - 50%
External 2: Voltage:
0 - 10V = 0 - 100%
of rated output voltage
Current limit
programming
(mode selected
by internal
switches)
Internal: Multiturn potentiometer  
External: Voltage:
0 - 10V = 0 - 110%
of rated output current
Remote On/Off Normal H: TTL level Isolated 5V, 100mA internal pull up supply
Normal L: TTL level
Forced load share Single wire connection between modules 0 - 5.5V signal indicates each module's current