SERIES HSP CURRENT HARMONICS, SOURCE TRANSIENTS AND EMI SPECIFICATIONS
|
Parameter
|
Document
|
Specification
|
IMMUNITY (1)
|
Radiated RF (Ampl. mod.)
|
EN 61000-4-3
|
10V/m, 80 - 1000MHz
|
Radiated RF (Pulse mod.)
|
EN 61000-4-3
|
10V/m, 900MHz
|
Magnetic Field
|
EN 61000-4-8
|
30A/M, 50Hz
|
Electrostatic Discharge
|
EN 61000-4-2
|
4KV (contact) 8KV (air)
|
Conducted RFI
|
EN 61000-4-6
|
10Vrms, 0.15 - 80MHz
|
Electrical Fast Transient
|
EN 61000-4-4
|
2KV, Tr/Th 5/50ns
|
Surge (CM, DM)
|
EN 61000-4-5
|
2KV (CM) Tr/Th 8/20μs
1KV (DM) Tr/Th 8/20μs
|
EMISSIONS
|
Conducted RF
|
FCC, Class A CISPR 22, Class A
|
0.45 - 30MHz
0.55 - 30MHz
|
Current Harmonics
|
EN 60555-2 and EN 61000-3-2
|
0 - 2KHz
|
(1) |
All immunity levels meet the requirements for heavy industrial applications per EN 50082-2 using Criteria A (no operational effect).
|
|