SERIES HSP INPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
a-c voltage, 1000W Models |
Nominal: |
100-250 Va-c
|
Single phase
|
Range: |
90-277 Va-c
|
Wide Range
|
a-c voltage, 1500W Models |
Nominal: |
200-250 Va-c
|
Single phase
|
Range: |
180-277 Va-c (2)
|
Wide Range
|
d-c voltage (1) |
1000W: |
125-420 Vd-c (1)
|
Polarity insensitive
|
1500W: |
250-420 Vd-c (1)
|
Polarity insensitive
|
Brownout Voltage |
1000W: |
75 Va-c
|
|
1500W: |
150 Va-c
|
Source Frequency |
Nominal: |
50-60 Hz
|
> 63Hz, input leakage current exceeds tabulated value
|
Range: |
47-440 Hz
|
Source Current |
`120V a-c: |
1000W: 11.0A rms
|
Typical
|
240V a-c: |
1000W: 5.5A rms
1500W: 8.0A rms
|
Power Factor (PF) |
`Typical: |
0.99
|
Any source, 25% to 100% load
|
Minimum: |
0.96
|
(1) |
Safety approval is for a-c operation only. |
(2) |
For operation of HSP 1500W with lower than nominal mains voltage, refer to Figure below for temperature and power derating; safety agency approvals are not applicable.
|
|