KLP 2400W MODEL TABLE
|
MODEL (3)
|
RATED VOLTAGE RANGE (1)
|
MAXIMUM CURRENT FOR RATED VOLTAGE
|
MINIMUM PROGRAMMABLE CURRENT
|
RATED CURRENT RANGE (1)
|
MAXIMUM VOLTAGE FOR RATED CURRENT
|
RIPPLE AND NOISE p-p (2)
|
EFFICIENCY @115V a-c
|
KLP 36-120 |
0-36V |
66A@36V |
0.8A |
0-60A |
20V@120A |
60 mV |
83% |
KLP 75-66 |
0-75V |
33A@75V |
0.4A |
0-33.3A |
36V@66.6A |
60 mV |
84% |
KLP 150-32 |
0-150V |
16A@150V |
0.2A |
0-16A |
75V@32A |
125 mV |
86% |
KLP 300-16 |
0-300V |
8A@300V |
0.1A |
0-8A |
150V@16A |
150 mV |
87% |
KLP 600-8 |
0-600V |
4A@600V |
0.05A |
0-4A |
300V@8A |
150 mV |
88% |
KLP 1000-4 |
0-1000V |
2.4A@1000V |
0.05A |
0-4A |
600V@4A |
150 mV |
88% |
(1) |
The maximum current and voltage are constrained by the 2400 watt power limitation, see Operating Region Figure.
|
(2) |
Bandwidth: 20MHz; low frequency ripple may be higher at loads less than 30 Watts.
|
(3) |
Standard models (no suffix) include built-in GPIB and RS 232 Interfaces. E-Series models (suffix E) include built-in GPIB and LAN Interfaces.
|
NOTE: |
The unit is shipped with a user-wirable mating connector for the IEC 320 style recessed power inlet connector. Optional line cords are available as accessories.
|
Model KLP 1000-4
KLP 2400W Operating Region
|