SERIES KHX SIGNALS AND FLAGS
|
Specification
|
Rating/Description
|
Condition
|
Status Flags
(Form C dry relay contacts)
|
POWER: |
Indicates low source voltage;signal asserted 5msec prior to loss of output voltage.
|
Both NO and NC available
|
OUTPUT: |
Indicates normal operation
|
OVER TEMP: |
Over temperature shutdown
|
FAN FAIL: |
Failure of internal fan
|
Status Indicators
Front panel LEDs (1)
|
POWER: |
Green
|
Lit when a-c is sufficient
|
DC FAIL: |
Red
|
Lit when output failure is detected
|
OVER TEMP: |
Yellow
|
Lit when thermostat activates
|
FAN FAIL: |
Red
|
Lit when fan failure is detected
|
Test Points
|
Monitor setpoint voltage |
0.1 x EOUT
|
|
Monitor setpoint current
|
0 - 5V full scale
|
Auxiliary Voltage (isolated)
|
|
4-5 - 5.5V d-c isolated 0 - 100 milliamperes
|
Present whenever housekeeping supply is operating
|