SERIES KHX OUTPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
Output Setting Range |
all except 48V: |
-80% to +10% (1)
|
Of nominal output
|
48V model: |
-80% to +25% (1)
|
Source Effect |
typ.: |
0.05%
|
Nominal ±15%
|
max.: |
0.1%
|
Load Effect |
typ.: |
0.05%
|
5% - 100% load, operation between 0 and 5% load results in increased ripple and degraded transient response.
|
max.: |
0.1%
|
Temperature Effect |
typ.: |
0.01%
|
Per degree C (0 to 50°C)
|
max.: |
0.02%
|
Combined Effect (source,
load, temperature & time) |
typ.: |
0.15%
|
|
max.: |
0.3%
|
Time Effect (drift) |
typ.: |
0.05%
|
0.5 - 8.5 hours
|
max.: |
0.1%
|
Startup Time |
max.: |
1 second
|
Any source/load
|
Recovery characteristics |
Excursion: |
<3% of normal output
|
50 - 100% load
|
Recovery: |
1000W: 100μsec
1500W: 300μsec
|
Return to 1% of setting |
Ride through |
min.: |
21.5 Milliseconds
|
From loss of source to flag signal
|
Hold up Time |
min.: |
5 Milliseconds
|
After signal flag
|
Overshoot |
turn on: |
+3% max
|
Any source, 5% - 100% load
|
turn off: |
none
|
Error Sense |
3.3V & 5V: |
0.25V
|
Voltage allowance per wire
|
all others: |
0.4V
|
Series connection (output floats) |
|
500V
|
Maximum voltage off ground
|
Parallel connection (for redundancy) |
|
Current shares within 5% of rated load
|
5% - 100% load
|
Selective overvoltage shutdown |
|
Adjustable 100% - 140% of nominal, factory set to 130%
|
Latched, reset by cycling source power off
|
Current limiting |
|
Constant Current mode Factory set 110% of IO max
|
Optional shutdown mode with 20 second delay
|
Remote on/off |
RC-1 |
Normally high
|
Isolated form C or TTL
|
RC-2: |
Normally low
|
Overtemperature |
|
Thermostat, auto restart
|
With hysteresis
|