   SERIES KHX CONTROL CHARACTERISTICS
Specification Rating/Description Condition
Voltage set
programming
(mode selected
by internal
switches)
(isolated)
Internal: Multiturn potentiometer The DC OK/DC FAIL fault detect window tracks the programmed output voltage; OVP trip unaffected.
External 1: Resistance,
0 - 10K = 100 - 50%
External 2: Voltage,
0 - 10V = 0 - 100% of
rated output voltage
Current limit
programming
(mode selected
by internal
switches)
Internal: Multiturn potentiometer  
External: Voltage,
0 - 10V = 0 - 110% of
rated output current
Remote
ON/OFF
Normal H: TTL level Isolated 5V, 100mA, internal pull up supply
Normal L: TTL level
Current share/
Forced Load share
  Single wire connection
between modules
0 - 5V signal indicates each modules current