SERIES KHX CONTROL CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
Voltage set programming
(mode selected by internal switches) (isolated)
|
Internal: |
Multiturn potentiometer
|
The DC OK/DC FAIL fault detect window tracks the programmed output voltage; OVP trip unaffected.
|
External 1: |
Resistance,
0 - 10K = 100 - 50%
|
External 2: |
Voltage,
0 - 10V = 0 - 100% of
rated output voltage
|
Current limit programming
(mode selected by internal switches)
|
Internal: |
Multiturn potentiometer
|
|
External: |
Voltage,
0 - 10V = 0 - 110% of
rated output current
|
Remote ON/OFF
|
Normal H: |
TTL level
|
Isolated 5V, 100mA, internal pull up supply |
Normal L: |
TTL level
|
Current share/ Forced Load share |
|
Single wire connection between modules
|
0 - 5V signal indicates each modules current
|