KHX CURRENT HARMONICS, SOURCE TRANSIENTS AND EMI SPECIFICATIONS
|
Parameter
|
Document
|
Specification
|
IMMUNITY (1)
|
Radiated RF (Ampl. Mod.)
|
EN 61000-4-3 (2)
|
10V/m, 80 - 1000MHz
|
Radiated RF (Pulse Mod.)
|
EN 61000-4-3 (2)
|
10V/m, 900MHz
|
Magnetic Field
|
EN 61000-4-8 (2)
|
30A/m, 50Hz
|
Electrostatic Discharge
|
EN 61000-4-2 (2)
|
4KV (contact) 8KV (air)
|
Conducted RFI
|
EN 61000-4-6 (2)
|
10Vrms, 0.15 - 80MHz
|
Electrical Fast Transient
|
EN 61000-4-4 (2)
|
2KV, Tr/Th = 5/50ns
|
Surge (CM, DM)
|
EN 61000-4-5 (2)
|
2KV (CM) Tr/Th = 8/20μs
2KV (DM) Tr/Th = 8/20μs
|
EMISSIONS
|
Conducted RF
|
FCC, Class A (2)
CISPR 22, Class A (2)
|
2KV, Tr/Th = 5/50ns
|
Current Harmonics
|
EN 60555-2 and EN 61000-3-2 (2)
|
0 - 2KHz
|
(1)
|
All immunity levels designed to meet the requirements for heavy industrial applications per EN 50082-2 using Criteria A (no operationsl effect).
|
(2)
|
Designed to meet.
|
|