   BIT 4886, BIT 802E GENERAL SPECIFICATIONS
Specification Rating/Description Condition
Output Voltage
(Main Channel)
High Range Programs BOP from
0 to ±rated value.
 
Low Range: Programs BOP from
0 to ±1/4 rated value.
 
Rise/Fall Times: < 100μS VOLT:MIN to VOLT:MAX
Output Impedance <0.5 Ohms  
Linearity Error (0 to +70°C) ±1/2 LSB ±1 LSB for BIT 4886
Temperature
Coefficient
Full Scale: ±35 ppm /°C max  
Zero: ±10 ppm /°C max High range
±30 ppm /°C max Low range
Voltage Readback: ±20μV / °C max High range
±10μV / °C max Low range
Current Readback: ±10 ppm /°C max High range
Optical Isolation 500V max Between analog and digital grounds
Data input Format Byte-Serial / IEEE  
Source Power Supplied by host
power supply
 
Resolutiion Main Channel
Programming:
15 bits (16 bits including ± sign)  
Limit Channel
Programming:
12 bits  
Readback: 15 bits (16 bits including ± sign)  
Linearity Programming: ±1 LSB  
Readback ±2 LSBs  
Data Readback
Accuracy
Voltage: 0.05% of max. voltage  
Current: 0.05% of max. current  
List Programming Step range: 500μs in 10 seconds  
Step accuracy: -5 to +20μs (1)  
Number of steps: 1002  
Rise/Fall Time: > 100μs  
Transient
Programming
Range: 500μs in 10 seconds  
Accuracy: -20 to +1200μs (1)  
Rise/Fall Time: > 100μs  
Environmental
Specifications
Operating Temp: 0 to 55° C  
Storage Temp: -20 to +85° C  
Shipping Weight 3 lbs. (1.4 Kg)  

(1) BIT 4886 accuracy is affected by GPIB and RS-232 communications. To attain these accuracies only the
      Serial poll command of the GPIB interface should be used while executing a transient or list.