   BOP Voltage Specifications with BIT 4886 or BIT 802E Installed
VOLTAGE
SPECIFICATION
BOP Model (1) (Arranged by Voltage Capability)
BOP 200-1 BOP 100-1
BOP 100-2
BOP 100-4
BOP 72-3
BOP 72-6
BOP 50-2
BOP 50-4
BOP 50-8
BOP 36-6
BOP 35-12
BOP 20-5
BOP 20-10
BOP 20-20
High Range Accuracy 24mV 12mV 8mV 6mV 4mV 2.4mV
Low Range Accuracy (2) 6mV 3mV 2mV 1.5mV 1mV 0.6mV
Positive Limit Accuracy 300mV 150mV 100mV 90mV 75mV 36mV
Measurement Accuracy 120mV 60mV 45mV 30mV 24mV 12mV

(1) Add D suffix for models with digital meter (standard).
(2) Low Range is defined as less than 1/4 of the rated value.

   BOP Current Specifications with BIT 4886 or BIT 802E Installed
CURRENT
SPECIFICATION
BOP Model (1) (Arranged by Current Capability)
BOP 20-20 BOP 36-12 BOP 20-10 BOP 50-8 BOP 36-6
BOP 72-6
BOP 20-5 BOP 50-4
BOP 100-4
BOP 72-3 BOP 50-2
BOP 100-2
BOP 100-1
BOP 200-1
High Range Accuracy (2) 20mA 6mA 5mA 4mA 1.2mA 1mA 0.5mA 0.36mA 0.25mA 0.12mA
Low Range Accuracy (2) (3) 0.75mA 0.5mA 0.3mA 0.25mA 0.2mA 0.15mA 0.12mA 0.08mA 0.06mA 0.03mA
Positive Limit Accuracy (2) 40mA 28mA 24mA 20mA 6mA 5mA 8mA 3mA 2mA 1mA
Measurement Accuracy (2) 20mA 14mA 12mA 5mA 3mA 2.5mA 2mA 1.5mA 1mA 0.5mA

(1) Add D suffix for models with digital meter (standard).
(2) Accuracy specifications apply only after one minute warm-up.
(3) Low Range is defined as less than 1/4 of the rated value.

   BIT 4886, BIT 802E Specifications
Specification Description
Output Voltage
(Main Channel)
High Range: Programs BOP to rated value.
Low Range: Programs BOP to 1/4 rated value.
Rise and Fall times
(VOLT:MIN to VOLT:MAX):
<100 microseconds
Temperature Coefficient Full scale:: ± 35 ppm/°C max
Zero: High Range: ±10 ppm/°C max
Low Range: ±30 ppm/°C max
Voltage Readback: High Range: ± 20?V/°C max
Low Range: ± 10?V/°C max
Current Readback: ±10 ppm/°C max
Optical Isolation Digital and Analog grounds can be separated by a maximum of 500 Volts.
Digital Input Format Byte-Serial/IEEE
Power Requirement Supplied by host power supply.
Resolution: Main Channel Programming: 15 bits (16 bits including ± sign)
Limit Channel Programming: 12 bits
Readback: 15 bits (16 bits including ± sign)
Linearity: Programming: ± 1 LSB
Readback: ± 2 LSBs
Data Readback
Accuracy:
Voltage: 0.05% of Max. Voltage
Current: 0.05% of Max. Current
List: Step Range: 500 microseconds to 10 seconds
Step Accuracy: -5 to +20 microseconds (1)
Number Of Steps: 1002
Rise/fall Time: >100 microseconds
Transient: Transient Range: 500 microseconds to 10 seconds
Transient Accuracy: -20 to +1200 microseconds (1)
Rise/fall Time: >100 microseconds
Environmental
Specifications:
Operating Temp.: 0 to 50° C
Storage Temp.: -20 to +85° C
(1) BIT 4886 ONLY: Accuracy is affected by GPIB and RS-232 communications. To attain these accuracies only the
      Serial poll command of the GPIB interface should be used while executing a transient or list.
PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com