To make the transition to our latest power supplies easier, Kepco's adapter plates allow the use of existing mounting holes (no drilling needed) - ideal for field replacements and upgrades. If note (7) does not list the one you need, contact Kepco.
|
NOTE: Users of the 0 - 100% programming feature of RKW 300W and RKW 600W models are recommended to use AE 800 models as replacements.
|
(1) |
Adjustable ±10% via potentiometer.
|
(2) |
Programmable from 30/40% to 105%.
|
(3) |
Programmable from 0 to 105%.
|
(4) |
12V/250A
|
(5) |
Adapter plates are available that permit mounting of AK, AE and HWS Series power supplies using the same mounting screw locations (no driliing). [REQUEST MOUNTING ADAPTER QUOTE]
MA RKW/HWS-300H is for mounting HWS300 models in place of horizntally-mounted 300W RKWs.
MA RKW/HWS-300V is for mounting HWS300 models in place of vertically-mounted 300W RKWs.
MA RKW/AK-350H is for mounting AK-350 models in place of horizntally-mounted 300W RKWs.
MA RKW/AK-350V is for mounting AK-350 models in place of vertically-mounted 300W RKWs.
MA RKW/AK-450H is for mounting AK-450 imodels in place of horizntally-mounted 300W RKWs.
MA RKW/AK-450V is for mounting AK-450 models in place of vertically-mounted 300W RKWs.
MA RKW/HWS-600H is for mounting HWS600 models in place of horizntally-mounted 600W RKWs.
MA RKW/HWS-600V is for mounting HWS600 models in place of vertically-mounted 600W RKWs.
MA RKW/AK-650H is for mounting AK-650 models in place of horizntally-mounted 600W RKWs.
MA RKW/AK-650V is for mounting AK-650 models in place of vertically-mounted 600W RKWs.
MA RKW/AE-800H is for mounting AE-800 models in place of horizntally-mounted 600W RKWs.
MA RKW/AE-800V is for mounting AE-800 models in place of vertically-mounted 600W RKWs.
MA RKW/AE-1500H is for mounting AE-1500 models in place of horizntally-mounted 1500W RKWs.
MA RKW/AE-1500V is for mounting AE-1500 models in place of vertically-mounted 1500W RKWs.
MA RKW/AK-1500H is for mounting AK-1500 models in place of horizntally-mounted 1500W RKWs.
MA RKW/AK-1500V is for mounting AK-1500 models in place of vertically-mounted 1500W RKWs.
|
(6) |
Current limited to 62.5A.
|
RKW PROGRAMMABLE MODEL TABLE
|
MODEL
|
OUTPUT VOLTAGE Volts
|
ADJUSTMENT RANGE Volts
|
OVP SETTING(1) Volts
|
OUTPUT CURRENT(2) Amps -10 to +50°C
|
CURRENT LIMIT(3) Amps
|
SHORT CIRCUIT CURRENT Amps
|
SWITCHING RIPPLE mV p-p
|
NOISE(4) mV p-p
|
EFFICIENCY (%) TYPICAL
|
100V a-c
|
200V a-c
|
300 WATT MODELS
|
RKW 3.3-70K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
70 |
73.5 - 91 |
90 |
80 |
120 |
68 |
72 |
RKW 5-60K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
60 |
63.0 - 78.0 |
82 |
80 |
120 |
74 |
78 |
RKW 12-27K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
27 |
28.4 - 35.1 |
35 |
120 |
150 |
76 |
80 |
RKW 15-22K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
22 |
23.1 - 28.6 |
29 |
120 |
150 |
77 |
81 |
RKW 24-14K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
14 |
14.7 - 18.2 |
20 |
150 |
200 |
80 |
84 |
RKW 28-12K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
12 |
12.6 - 15.6 |
17 |
150 |
200 |
80 |
84 |
RKW 48-7K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
7 |
7.4 - 9.1 |
11 |
200 |
300 |
81 |
85 |
600 WATT MODELS
|
RKW 3.3-150K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
150 |
156 - 186 |
180 |
80 |
120 |
74 |
78 |
RKW 5-120K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
120 |
126 - 156 |
160 |
80 |
120 |
76 |
81 |
RKW 12-53K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
53 |
55.6 - 68.9 |
65 |
150 |
200 |
80 |
84 |
RKW 15-43K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
43 |
45.1 - 55.9 |
55 |
150 |
200 |
81 |
85 |
RKW 24-27K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
27 |
28.3 - 35.1 |
35 |
200 |
300 |
82 |
86 |
RKW 28-23K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
23 |
24.1 - 29.8 |
29 |
200 |
300 |
82 |
86 |
RKW 48-13K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
13 |
13.7 - 16.9 |
19 |
300 |
400 |
84 |
87 |
1500 WATT MODELS
|
RKW 3.3-375K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
375 |
390 - 430 |
430 |
100 |
200 |
73 |
77 |
RKW 5-300K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
300 |
315 - 350 |
350 |
100 |
200 |
77 |
82 |
RKW 12-125K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
125 |
130 - 140 |
152 |
150 |
200 |
80 |
84 |
RKW 15-100K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
100 |
105 - 115 |
135 |
150 |
200 |
82 |
86 |
RKW 24-65K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
65 |
68 - 72 |
80 |
200 |
300 |
82 |
86 |
RKW 28-55K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
55 |
57.7 - 63.2 |
70 |
200 |
300 |
82 |
86 |
RKW 48-32K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
32 |
33.6 - 36.8 |
45 |
300 |
400 |
84 |
88 |
(1) An overvoltage shuts down the output. Recover by resetting the RC terminals. The overvoltage setting tracks the REF voltage.
(2) See Ratings vs Temperature.
(3) The current limit is rectangular. If overcurrent persists for more than 30 Seconds, the output shuts down. Reset by resetting the RC terminals.
(4) Bandwidth 100MHz. Ripple and noise will be approximately 1.5 times the values in the operating temperature range -10 to 0°C. The ripple and noise values tabulated are valid when the output is derated as shown in Ratings vs Temperature. from -10 to 0°C.
|
|