HWS ZERO UP PROGRAMMABLE MODEL TABLE
|
MODEL
|
OUTPUT VOLTAGE Volts
|
ADJUSTMENT RANGE Volts
|
OVP SETTING(1) Volts
|
OUTPUT CURRENT(2) Amps -10 to +50°C
|
RIPPLE NOISE (3) mV p-p
|
EFFICIENCY (%) TYPICAL
|
100V a-c
|
200V a-c
|
300 WATT MODELS
|
HWS300-5-27311 |
5 |
0 - 5.6 |
6.25 - 7.25 |
60 |
120 |
79 |
82 |
HWS300-12-27312 |
12 |
0 - 14.4 |
15.0 - 17.4 |
27 |
120 |
80 |
83 |
HWS300-15-27313 |
15 |
0 - 18.0 |
18.8 - 21.8 |
22 |
120 |
82 |
85 |
HWS300-24-27314 |
24 |
0 - 28.8 |
30.0 - 34.8 |
14 |
150 |
82 |
85 |
HWS300-48-27315 |
48 |
0 - 52.8 |
55.2 - 64.8 |
7 |
200 |
82 |
85 |
600 WATT MODELS (4)
|
HWS600-12-27316 |
12 |
0 - 14.4 |
15.0 - 17.4 |
53 |
120 |
80 |
83 |
HWS600-15-27317 |
15 |
0 - 18.0 |
18.8 - 21.8 |
43 |
150 |
82 |
85 |
HWS600-24-27318 |
24 |
0 - 28.8 |
30.0 - 34.8 |
27 |
150 |
82 |
85 |
HWS600-48-27319 |
48 |
0 - 52.8 |
55.2 - 64.8 |
13 |
200 |
82 |
85 |
(1)
|
OVP operates within 125% to 145% (115% to 135% for HWS300-48-27315 and HWS600-48-27319) of the rated output voltage value (OVP is fixed and cannot be adjusted). When OVP triggers, the output shuts down. Recover by removing power to the unit for a few minutes, then reapply input power. An alternative is to use CNT (remote on/off) to set the output OFF, then ON.
|
(2)
|
See Ratings vs Temperature.
|
(3)
|
The ripple and noise values tabulated are valid when the output is derated as shown in Ratings vs Temperature. from -10 to 0°C.
|
(4)
|
For 5V 600W Zero Up model, consult factory.
|
|