   HWS ZERO UP PROGRAMMABLE MODEL TABLE
MODEL OUTPUT
VOLTAGE
Volts
ADJUSTMENT
RANGE
Volts
OVP
SETTING(1)
Volts
OUTPUT
CURRENT(2)
Amps
-10 to +50°C

RIPPLE
NOISE (3)
mV p-p
EFFICIENCY (%)
TYPICAL
100V a-c 200V a-c
300 WATT MODELS
HWS300-5-27311 5 0 - 5.6 6.25 - 7.25 60 120 79 82
HWS300-12-27312 12 0 - 14.4 15.0 - 17.4 27 120 80 83
HWS300-15-27313 15 0 - 18.0 18.8 - 21.8 22 120 82 85
HWS300-24-27314 24 0 - 28.8 30.0 - 34.8 14 150 82 85
HWS300-48-27315 48 0 - 52.8 55.2 - 64.8 7 200 82 85
600 WATT MODELS (4)
HWS600-12-27316 12 0 - 14.4 15.0 - 17.4 53 120 80 83
HWS600-15-27317 15 0 - 18.0 18.8 - 21.8 43 150 82 85
HWS600-24-27318 24 0 - 28.8 30.0 - 34.8 27 150 82 85
HWS600-48-27319 48 0 - 52.8 55.2 - 64.8 13 200 82 85
(1) OVP operates within 125% to 145% (115% to 135% for HWS300-48-27315 and HWS600-48-27319) of the rated output voltage value (OVP is fixed and cannot be adjusted). When OVP triggers, the output shuts down. Recover by removing power to the unit for a few minutes, then reapply input power. An alternative is to use CNT (remote on/off) to set the output OFF, then ON.
(2) See Ratings vs Temperature.
(3) The ripple and noise values tabulated are valid when the output is derated as shown in Ratings vs Temperature. from -10 to 0°C.
(4) For 5V 600W Zero Up model, consult factory.