HWS ZERO UP PROGRAMMABLE GENERAL SPECIFICATIONS
|
Specification
|
Rating/Description
|
Condition
|
Temperature |
Operating: |
-10 to +70°C
|
Rated load. See Derating Curves
|
Startup: |
-20 to -10°C
|
|
Storage: |
-30 to +85°C
|
|
Cooling
|
internal fan
|
|
Humidity |
Operating: |
10 to 90% RH
|
Non-condensing
|
Non-operating: |
10 to 95% RH
|
non-condensing
|
Shock
|
<196.1 m/s2
|
|
Vibration
|
10-55 Hz (1 minute sweep), constant <19.6 m/s2 X, Y Z axes 1 hour
|
non-operating
|
Overvoltage Protection
|
Shutdown between 125% and 145% (1) of max d-c output
|
Fixed, not adjustable. Recovery required (2)
|
Overcurrent Protection
|
Shutdown if >105% (3) of max d-c output current
|
Fixed, not adjustable. Automatic recovery when condition removed.
|
Overtemperature protection
|
Shutdown
|
Recovery required (4)
|
Dimensions |
300W: |
2.4 x 3.23 x 6.5 inches
61 x 82 x 165.1 mm
|
W x H x D
|
600W: |
3.94 x 3.23 x 6.5 inches
100.1 x 82 x 165.1 mm
|
W x H x D
|
Weight |
300W: |
2.2 lbs (1 Kg)
|
|
600W: |
3.53 lbs (1.6 Kg)
|
|
NOTES:
|
(1) |
115 to 135% for HWS300-48-27315.
|
(2) |
Recover either by cycling input power or setting remote ON/OFF to OFF, then ON.
|
(3) |
119% of max d-c output current for HWS300-24-27314.
|
(4) |
To recover, disconnect input power, allow cooldown, then reconnect input power.
|
|