Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   SERIES ATE GENERAL SPECIFICATIONS
Specification Rating/Description Condition
CONTROL
Type Voltage: Variable input, fixed gain  
Current: Differential comparison  
Voltage Local: 10-turn precision rheostat  
Remote Analog: 0 to 1 Volt d-c  
Remote Digital: Use SN or SNR interface 12-bit, listen only
Current Local: 10-turn precision rheostat  
Remote Analog: 0 to 1 Volt d-c  
Remote Digital: Use SN or SNR interface 12-bit, listen only
Dynamics Normal (slow): dV/dt = I/C See model table for tabulated value of C
Fast mode: See dynamic specifications table  