Cotek MP Series medical power supplies feature class II isolation level for 5~60W single and dual output (45/60W) models. These power supplies can be installed into patient contact medical equipment and still comply with Class B per EMI regulations. Short circuit, overload, overvoltage and overtemperature protections are standard. General medical or industrial usage that requires low leakage current, general electronic applications, and low profile IT equipment are all suitable for integrating these on-board type PSU onto the main control PCB of the final system. The MP comes with a 3 years warranty.
Features:
- 5W, 10W, 15W, 20W, 45W, 45W Dual Output, 60W, 60W Dual Output, 150W, 250W, 350W, 450W Models
- Green design, No-load power consumption:
- < 0.3W (Cotek MP-05, MP-10, MP-15, MP-20)
- < 0.5W (Cotek MP-45)
- Universal AC input / Full range (Cotek MP-150, MP-250, MP-350, MP-450 include active PFC)
- Protections:
- Overvoltage, overload, short-circuit
- Brown-out (low AC input voltage) (Cotek MP-05, MP-10, MP-15, MP-20, MP-45, MP-60)
- Medical safety approved
- UL60601-1/IEC60601-1/EN60601-1:2006
(Cotek MP-45, MP-60)
- ANSI / AAMI ES 60601-1 / TÜV EN 60601-1; IEC 60601-1 / MOPP (Cotek MP-150, MP-250, MP-350, MP-450)
- Isolation class II (Cotek MP-05, MP-10, MP-15, MP-20, MP-45)
- All using 105°C long life electrolytic capacitors (Cotek MP-05, MP-10, MP-15, MP-20, MP-45, MP-60)
- High operation temperature, up to 70°C
- 100% full load burn-in test (Cotek MP-05, MP-10, MP-15, MP-20, MP-45, MP-60)
- Withstand 2G vibration test
- Cooling by free air convection
- Cotek MP-150: 100W (150W with 10.5 CFM forced air)
- Cotek MP-250: 150W (250W with 23.5 CFM forced air)
- Cotek MP-350: 200W (350W with 20 CFM forced air)
- Cotek MP-450: 300W (450W with 23.5 CFM forced air)
- High efficiency, long life and high reliability (Cotek MP-45, MP-60)
- Dual output models (Cotek MP-45, MP-60)
- Built-in auxiliary power for fan (Cotek MP-150, MP-250, MP-350, MP-450)
- Power OK signal (Cotek MP-250, MP-450)
- Remote ON / OFF, Remote sense functions (Cotek MP-450)
- 3 year warranty
- RoHS Compliant
- Detailed Specifications (PDF)
-
|
|
5W Cotek MP-05 Series
Green design, No-load power consumption < 0.3W
Universal AC input / Full range
5V, 12V, 15V, 24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
Medical safety approved
Isolation class II
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
3 year warranty
|
5W Cotek MP-05 Models
5V: Cotek MP-05-05
12V: Cotek MP-05-12
15V: Cotek MP-05-15
24V: Cotek MP-05-24
|
|
10W Cotek MP-10 Series
Green design, No-load power consumption < 0.3W
Universal AC input / Full range
5V, 12V, 15V, 24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
Medical safety approved
Isolation class II
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
3 year warranty
|
10W Cotek MP-10 Models
5V: Cotek MP-10-05
12V: Cotek MP-10-12
15V: Cotek MP-10-15
24V: Cotek MP-10-24
|
|
15W Cotek MP-15 Series
Green design, No-load power consumption < 0.3W
Universal AC input / Full range
5V, 12V, 15V, 24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
Medical safety approved
Isolation class II
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
3 year warranty
|
15W Cotek MP-15 Models
5V: Cotek MP-15-05
12V: Cotek MP-15-12
15V: Cotek MP-15-15
24V: Cotek MP-15-24
|
|
20W Cotek MP-20 Series
Green design, No-load power consumption < 0.3W
Universal AC input / Full range
5V, 12V, 15V, 24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
Medical safety approved
Isolation class II
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
3 year warranty
|
20W Cotek MP-20 Models
5V: Cotek MP-20-05
12V: Cotek MP-20-12
15V: Cotek MP-20-15
24V: Cotek MP-20-24
|
|
45W Cotek MP-45 Series
Green design, No-load power consumption < 0.5W
Universal AC input / Full range
5V, 12V, 15V, 24V, 48V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
UL60601-1/IEC60601-1/EN60601-1 :2006 medical safety approved
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
High efficiency, long life and high reliability
3 year warranty
|
45W Cotek MP-45 Models
5V: Cotek MP-45-05
12V: Cotek MP-45-12
15V: Cotek MP-45-15
24V: Cotek MP-45-24
48V: Cotek MP-45-48
|
|
45W Cotek MP45 Dual Output Series
Universal AC input / Full range
5V/12V, 5V/24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
ANSI/AAMI ES 60601-1/TÖV EN 60601-1: 2006; IEC 60601-1/2 xMOPP medical safety approved
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
High efficiency, long life and high reliability
3 year warranty
|
45W Cotek MP45 Dual Output Models
5V/12V: Cotek MP45-05F
5V/24V: Cotek MP45-05K
|
|
60W Cotek MP-60 Series
Universal AC input / Full range
5V, 12V, 15V, 24V, 48V models
4" x 2" footprint
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
UL60601-1/IEC60601-1/EN60601-1 :2006 medical safety approved
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
High efficiency, long life and high reliability
3 year warranty
|
60W Cotek MP-60 Models
5V: Cotek MP-60-05
12V: Cotek MP-60-12
15V: Cotek MP-60-15
24V: Cotek MP-60-24
48V: Cotek MP-60-48
|
|
60W Cotek MP60 Dual Output Series
Universal AC input / Full range
5V/12V, 5V/24V models
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
ANSI/AAMI ES 60601-1/TÖV EN 60601-1: 2006; IEC 60601-1/2 xMOPP medical safety approved
All using 105°C long life electrolytic capacitors
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Cooling by free air convection
High efficiency, long life and high reliability
3 year warranty
|
60W Cotek MP60 Dual Output Models
5V/12V: Cotek MP60-05F
5V/24V: Cotek MP60-05K
|
|
150W Cotek MP-150 Series
Universal AC input / Full range with active PFC
5V, 12V, 15V, 24V, 48V models
4" x 2" footprint
Protections: Overvoltage, overload, short-circuit, brown-out (low AC input voltage)
Medical safety approval: ANSI/AAMI ES 60601-1/
TÜV EN 60601-1; IEC 60601-1/MOPP
High operation temperature up to 70°C
100% full load burn-in test
Withstand 2G vibration test
Convection cooling to 100W, up to 150W with 10.5 CFM forced air
Built-in fan supply
High efficiency, long life and high reliability
3 year warranty
|
150W Cotek MP-150 Models
5V: Cotek MP-150-05
12V: Cotek MP-150-12
15V: Cotek MP-150-15
24V: Cotek MP-150-24
48V: Cotek MP-150-48
|
|
250W Cotek MP-250 Series
Universal AC input / Full range with active PFC
5V, 12V, 15V, 24V, 48V models
5" x 3" footprint
Protections: Overvoltage, overload, short-circuit
Medical safety approval: ANSI/AAMI ES 60601-1/
TÜV EN 60601-1; IEC 60601-1/MOPP
High operation temperature up to 70°C
Withstand 2G vibration test
Convection cooling to 150W, up to 250W with 23.5 CFM forced air
Built-in auxiliary power supply for fan
Power OK signal
3 year warranty
|
250W Cotek MP-250 Models
5V: Cotek MP-250-05
12V: Cotek MP-250-12
15V: Cotek MP-250-15
24V: Cotek MP-250-24
48V: Cotek MP-250-48
|
|
350W Cotek MP-350 Series
Universal AC input / Full range with active PFC
5V, 12V, 15V, 24V, 48V models
5" x 3" footprint
Protections: Overvoltage, overload, short-circuit
Medical safety approval: ANSI/AAMI ES 60601-1/
TÜV EN 60601-1; IEC 60601-1/MOPP
High operation temperature up to 70°C
Withstand 2G vibration test
Convection cooling to 200W, up to 350W with 20 CFM forced air
Built-in auxiliary power supply for fan
Power OK signal
3 year warranty
|
350W Cotek MP-350 Models
5V: Cotek MP-350-05
12V: Cotek MP-350-12
15V: Cotek MP-350-15
24V: Cotek MP-350-24
48V: Cotek MP-350-48
|
|
450W Cotek MP-450 Series
Universal AC input / Full range with active PFC
5V, 12V, 15V, 24V, 48V models
7" x 4" footprint
Protections: Overvoltage, overload, short-circuit
Medical safety approval: ANSI/AAMI ES 60601-1/
TÜV EN 60601-1; IEC 60601-1/MOPP
High operation temperature up to 70°C
Withstand 2G vibration test
Convection cooling to 300W, up to 450W with 23.5 CFM forced air
Built-in auxiliary power supply for fan
Power OK signal
Remote ON/OFF, remote sense functions
3 year warranty
|
450W Cotek MP-450 Models
5V: Cotek MP-450-05
12V: Cotek MP-450-12
15V: Cotek MP-450-15
24V: Cotek MP-450-24
48V: Cotek MP-450-48
|
|
|