BOP HIGH VOLTAGE MODEL TABLE
|
MODEL (1)
|
d-c Output Range
|
Closed Loop Gain
|
Output Impedance
|
EO max
|
IO max
|
Voltage Channel GV (V/V)
|
Current Channel GA (A/V)
|
Series R
|
Series L (2)
|
Shunt R
|
Shunt C (3)
|
BOP 500DM (4) |
±500V |
±80mA |
50 |
8.0 |
0.05Ω |
20mH |
100MΩ |
0.3µF |
BOP 1000DM (5) |
±1000V |
±40mA |
100 |
4.0 |
0.2Ω |
50mH |
400MΩ |
0.4µF |
(1) Suffix "M" specifies anaolg meters, Suffix "DM" specifies digital meters.
(2) For determining dynamic impedance in voltage mode.
(3) For determining dynamic impedance in current mode.
(4) BOP 500M (analog meters) available only while supplies last.
(5) BOP 1000M (analog meters) is no longer available; use BOP 1000DM instead.
|