   BOP HIGH VOLTAGE MODEL TABLE
MODEL (1) d-c Output Range Closed Loop Gain Output Impedance
EO max IO max Voltage
Channel
GV
(V/V)
Current
Channel
GA
(A/V)
Series R Series L (2) Shunt R Shunt C (3)
BOP 500DM (4) ±500V ±80mA 50 8.0 0.05Ω 20mH 100MΩ 0.3µF
BOP 1000DM (5) ±1000V ±40mA 100 4.0 0.2Ω 50mH 400MΩ 0.4µF

(1) Suffix "M" specifies anaolg meters, Suffix "DM" specifies digital meters.
(2) For determining dynamic impedance in voltage mode.
(3) For determining dynamic impedance in current mode.
(4) BOP 500M (analog meters) available only while supplies last.
(5) BOP 1000M (analog meters) is no longer available; use BOP 1000DM instead.