SERIES BHK-MG INPUT CHARACTERISTICS
|
Specification
|
Rating/Description
|
Condition
|
40W
|
200W
|
a-c Voltage |
Nominal: |
115/230V a-c
|
Single phase switch selectable
|
Range: |
105-125/210-250V a-c
|
Frequency |
Nominal: |
50/60Hz
|
|
Range: |
47-63Hz
|
Current |
115V a-c: |
1A
|
<4.0A a-c
|
At nominal power
|
230V a-c: |
0.6A
|
<2.1A a-c
|
Withstand Voltage |
All models: |
1350V a-c/1 min.
|
Between shorted inputs and chassis
|
300V models: |
1950V d-c/1 min.
|
Between shorted outputs and chassis
|
500V models: |
2250V d-c/1 min.
|
1000V models: |
2800V d-c/1 min.
|
2000V models: |
Chassis Connection to Ground Resistance
|
10 mOhms max.
|
Between ground input connection and chassis @ 30A.
|
Leakage Current
|
25 μA rms/100μAp-p, for
115V a-c input voltage (chassis to earth ground)
|