- 115/230V a-c operation without user intervention: Special flyback circuit accepts any input voltage from 90V to 264V a-c.
- Current trade-off: Current may be increased from one of the outputs at the expense of the others, within the limits defined by the output curves.
- Adjustable voltage: Internal trimmer accessible through the case allows manual adjustment of the principal voltage setting. The auxiliary output tracks.
- Overvoltage protection for principal output: Shuts down all outputs if output voltage is forced beyond the set limit.
- Holding time: Output is sustained by internally stored energy for 30 milliseconds typically, 20 milliseconds minimum.
- Built-in EMI filter: Attenuates conducted noise below the requirements of FCC Class B.
- Safety: All models recognized by UL to UL 1950, certified by CSA to CSA 1402C, and approved by TÜV Rheinland to EN 60950.
- DIN Rail mountable
|