Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   SERIES HSM OUTPUT CHARACTERISTICS
Specification Rating/Description Condition
Voltage set
programming
(mode selected
by internal
switches)
(isolated)
Internal: Multiturn potentiometer The DC OK/DC FAIL fault detect window tracks the programmed output voltage; OVP trip unaffected.
External 1: Resistance,
0 - 50K = 100 - 50%
External 2: Voltage,
0 - 10V = 0 - 100% of
rated output voltage
Current limit
programming
(mode selected
by internal
switches)
Internal: Multiturn potentiometer  
External: Voltage,
0 - 10V = 0 - 110% of
rated output current
Remote
ON/OFF
Normal H: TTL level Isolated 5V, 100mA, internal pull up supply
Normal L: TTL level
Forced Load share   Single wire connection
between modules
0 - 5.5V signal indicates each module's current
PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com