- Active soft-start circuit: Limits a-c turn-on surge.
- Remote error sensing: Compensates for voltage drops to 0.35V per wire.
- Adjustable voltage: Internal trimmer accessible through the optional case allows manual adjustment of the voltage setting.
- Remote voltage control: Provision is made for an external resistor to trim the output voltage setting.
- Overvoltage protection: Power is shut off if output voltage is forced beyond the set limit.
- Rectangular current limiting so you can drive non-linear loads.
- Holding time: Output is sustained by internally stored energy for 30 milliseconds typically, 20 milliseconds minimum.
- Built-in EMI filter: Attenuates conducted noise below the requirements of FCC Class B. Optional perforated metal covers attenuate radiated noise and provide protection.
- Safety: All models recognized by UL, certified by CSA, and approved by TÜV Rheinland to meet EN 60950.
- Connections: Input and output connections are via MOLEX pin header. Mating connectors (with 1m leads crimped in place) available.
- DIN Rail mountable
|