OVERVIEW OF DIN RAIL MOUNTABLE PRODUCTS
|
SINGLE
OUTPUT
AC
TO
DC
|
SERIES HSM
1000, 1500W
3.3V-48V d-c
|
SERIES RKW PROGRAMMABLE
300, 600, 1500W
3.3V-48V d-c
|
SERIES RKW OPEN FRAME
30, 50, 100, 150W
3.3V-48V d-c
|
SERIES RTW
50, 100W, 300W
3.3V-48V d-c
|
SERIES RKE
1500W
24V, 48V d-c
|
SERIES KDN (no kit required)
24V d-c
5, 10, 20A d-c
|
PROGRAM- MABLE
|
SERIES RKW PROGRAMMABLE
300, 600, 1500W
3.3V-48V d-c
|
SERIES PAT
20W
0-7, 0-15, 0-21, 0-40, 0-100V d-c
|
SERIES PTR
60W
0-7, 0-15, 0-21, 0-40, 0-100V d-c
|
|
Series RKW Programmable are single-output, industrial grade switchers available in three sizes: 300, 600 and 1500 watts. Nominal output voltages available are 3.3, 5, 12, 15, 24, 28, and 48V d-c.
|
|
Model | Mounting Direction (See Note 2) | Part Number for DIN RAIL MOUNTING KIT | Model Number for Power Supply with FACTORY-INSTALLED DIN RAIL MOUNTING
|
RKW 300 Watts
|
LONG |
DIN RKW 300L |
[*]-DL |
SHORT |
DIN RKW 300S |
[*]-DS (see Note 3) |
PERPENDICULAR |
DIN RKW 300P |
[*]-DP |
RKW 600 Watts
|
LONG |
DIN RKW 600L |
[*]-DL |
SHORT |
Not avaialble |
PERPENDICULAR |
DIN RKW 600P |
[*]-DP |
RKW 1500 Watts
|
LONG |
DIN RKW 1500L |
[*]-DL |
SHORT |
Not avaialble |
PERPENDICULAR |
Not avaialble |
[*] Insert basic model number from MODEL table
NOTE 1: Please contact Kepco at hq@kepcopower.com for more information.
NOTE 2: Mounting direction illustrated in Figures 1, 2, and 3.
NOTE 3: Table 1 lists the minimum clearance required to install RKW Programmable power supplies on the DIN rail when the short (S) option is chosen. Figure 4 illustrates the clearance requirements. Table 1 has been generated using the following formula:
D = B x sin20° where B = (L/2)-3 and L is measured in inches
TABLE 1 - DIN RAIL CLEARANCE REQUIREMENTS FOR RKW PROGRAMMABLE SERIES |
MODEL | L (length in inches) (See Figure 4) | B [(L/2)-3] | D (Clearance in inches) (See Figure 4) |
DIN RKW 300W-DS |
6.89 |
0.45 |
0.15 |
DIN RKW 600W-DS |
7.87 |
0.94 |
0.32 |
DIN RKW 1500W-DS |
11.81 |
2.91 |
0.99 |
|