   HSF-1UR MODEL TABLE: 50W, 100W, 150W
MODEL OUTPUT
VOLTS(1)
(V d-c)
ADJUSTMENT
RANGE
(V d-c)
OVP
SETTING
(V d-c)
OUTPUT
CURRENT(1)
(A d-c)
0-40C
OVERCURRENT
LIMIT(2)
(A d-c)
SW
RIPPLE
(mV p-p)
typ.
NOISE
(spike)
(mV p-p)
max.
50 WATT MODELS
HSF 3.3-10-1UR(3) 3.3 2.8 - 3.4 3.4 - 4.5 10 10.5 80 120
HSF 5-10-1UR 5 4.3 - 5.3 5.2 - 6.5 10 10.5 80 120
HSF 12-4.3-1UR 12 11.4 - 12.6 13.2 - 15.2 4.3 4.5 100 150
HSF 15-3.5-1UR 15 13.5 - 16.5 16.8 - 18.8 3.5 3.6 100 150
HSF 24-2.2-1UR 24 22.5 - 25.5 26.8 - 30.3 2.2(5) 2.3(6) 100 150
HSF 28-1.8-1UR(4) 28 22.4 - 30.2 32.0 - 35.0 1.8 1.9 150 200
HSF 48-1.1-1UR 48 45.0 - 51.0 54.8 - 59.9 1.1 1.15 200 300
100 WATT MODELS
HSF 3.3-25-1UR(3) 3.3 2.8 - 3.5 3.4 - 4.5 25 26.2 80 120
HSF 5-20-1UR 5 4.3 - 5.3 5.2 - 6.5 20 21.0 80 120
HSF 12-8.4-1UR 12 11.4 - 12.6 13.2 - 15.2 8.4 8.82 100 150
HSF 15-6.7-1UR 15 13.5 - 16.5 16.8 - 18.8 6.7 7.03 100 150
HSF 24-4.2-1UR 24 19.2 - 26.0 26.5 - 30.0 4.2 4.68 150 200
HSF 28-3.5-1UR 28 26.5 - 29.5 29.7 - 34.7 3.5 3.8 150 200
HSF 48-2-1UR 48 44.0 - 52.0 54.5 - 59.5 2 2.2 200 300
150 WATT MODELS
HSF 3.3-30-1UR(3) 3.3 2.8 - 3.4 3.4 - 4.5 30 38.5 80 120
HSF 5-30-1UR 5 4.3 - 5.3 5.2 - 6.5 30 33.0 80 120
HSF 12-12-1UR 12 9.8 - 13.0 13.2 - 15.2 12 13.7 100 150
HSF 15-10-1UR 15 12.3 - 16.5 16.8 - 18.8 10 11.0 100 150
HSF 24-6.3-1UR 24 19.2 - 26.0 26.5 - 30.3 6.3(7) 10.5 150 200
HSF 28-5.3-1UR 28 23.0 - 30.2 31.5 - 34.8 5.3 5.94 150 200
HSF 48-3.1-1UR 48 40.2 - 52.2 54.5 - 59.8 3.1 3.52 200 300
(1) See Temperature vs Power curve. Maximum Power Rating (W) = Nominal Output Volts (V) x Maximum Output Current (A). Reducing voltage allows operation without degradation at higher current as long as maximum power rating is not exceeded.
(2) Overcurrent Limit is rectangular (50W) or hiccup type (100W, 150W). After the overload is removed, output is automatically restored.
(3) Identical units may be paralleled, however forced current sharing is not available.
(4) T, C, X and Y Suffix models only.
(5) 3.2A Peak (Peak current and thermal protection applicable to 24V standard (no options) and C suffix models only; see 24V Peak Current Requirements).
(6) 3.3A min for 24V standard (no suffix) and C suffix 50W models only.
(7) 10A Peak (Peak current and thermal protection applicable to 24V standard (no options) and C suffix models only; see 24V Peak Current Requirements).