   HSF-A MODEL TABLE: 1500W
MODEL(1) OUTPUT
VOLTS
(V d-c)
ADJUSTMENT
RANGE
Front Panel
Trimpot
(V d-c)
MAX OUTPUT
CURRENT/POWER(2)
(%)
OVERVOLTAGE
PROTECTION
(OVP)(3)
CURRENT
LIMIT
SETTING(4)
(A d-c)
EFFICIENCY
(typ.)
(%)
RIPPLE/
NOISE(5)

(mV p-p)
SENSE
RESISTOR
(IMON)
(Ohms)
90-100V
a-c Input(6)
100-264V
a-c Input(7)
1500 WATT MODELS (Suffix A, AM)
HSF 15-100A, AM 15 TBD TBD TBD 120% 7% of VSET TBD TBD TBD TBD
HSF 24-50A, AM 24 0 - 30.5 90 - 100 105 120% 7% of VSET 52.5 89 300 0.002
HSF 36-42A, AM 36 0 - 36.8 90 - 100 105 120% 7% of VSET 43.7 89 360 0.002
HSF 48-32A, AM 48 0 - 49.4 90 - 100 105 120% 7% of VSET 32.8 90 480 0.005
HSF 60-25A, AM 60 0 - 62.0 90 - 100 105 120% 7% of VSET 26.2 91 600 0.005
(1) To specify digital front panel meter, add suffix "M" to model number, e.g., HSF 24-50AM.
(2) See output power vs temperature and input voltage ratings.
(3) Variable OVP at output terminals: 120% 7% of VSET.
(4) Protection type: Latch-style (recovery after reset AC power ON or inhibit).
(5) Ripple and noise are measured at 20MHz of bandwidth by using a 12-inch twisted pair wire terminated with a 1 uF ceramic capacitor.